CabinetModule CR2014
14
Characteristics of the inputs/outputs, test standards and regulations
7.3
Control systems
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
19.03.2010
We reserve the right to make technical alterations without prior notice!
CR2014 / page 3
CR2014
Characteristics of the inputs / outputs
Inputs
Channels 1...4, channels 9...12
• 8 inputs for positive sensor signals
For each input the pins +U
B
and Bin INx are available
Channels 7...8, channels 15...16
• 4 inputs for positive sensor signals
Can be used as an alternative to the 4 outputs.
For input and output one pin is available (double configuration).
The inputs can be used to read back the output signals.
Current consumption
I
IN
= 4 mA
(for U
B
= 10 V)
I
IN
= 17 mA
(for U
B
= 30 V)
Switching threshholds
HIGH = 8 V
LOW = 2.5 V
Switching frequency
25 Hz max.
(for ti = tp)
Channels 5...6, channels 13...14
• 4 inputs
for absolute value measurement 0...5 V
For each input the pins Ana INx and GND are available
Input resistance
typ. 720 k
Ω
Resolution
10 bits
Accuracy
typ. ± 2 LSB
Outputs
Channels 7, 15
• 2 positive-switching outputs; short-circuit and overload protected;
the supply voltage U
B
is switched without additional fuse.
The output states can be read back (see inputs).
For each input the pins Bin OUTx and GND are available.
When inductive loads are switched, free-wheeling diodes must be connected in
parallel with the load!
Switching current
max. 500 mA
Channels 8, 16
• 2 PWM outputs (high side), variable frequency
PWM frequency
20...250 Hz
Pulse duty factor
0...1000 ‰
Resolution
1 ‰
Switching current
max. 500 mA
Test standards and regulations
Immunity to
to ISO 7637-2, pulses 2a, 3a, 3b, 4, severity level 4, function state A
conducted interference
to ISO 7637-2, pulse 5, severity level 3, function state A
to ISO 7637-2, pulse 1, 2b, severity level 4, function state C
Immunity to interfering fields
to directive 06/28/EC at 100V/m (e1 type approval)
and EN 61000-6-2: 2005 (CE)
Interference emission
to directive 06/28/EC (e1 type approval)
and EN 61000-6-3: 2007 (CE)
\DATEN\100\DB-FORM—PZD/03/12/96