CabinetModule CR2014
10
Manufacturer-specific profiles; Idx 2000 to 6FFF
6.4
Parameters
Index in object
directory
Default value
(factory preset)
Change saved
automatically
Change
effective
Config� channel 1
2000 01
0x01 (Bin IN)
adjustable
after PreOp
Config� channel 2
2000 02
0x01 (Bin IN)
Config� channel 3
2000 03
0x01 (Bin IN)
Config� channel 4
2000 04
0x01 (Bin IN)
Config� channel 5
2000 05
0x03 (Ana IN absolute)
Config� channel 6
2000 06
0x03 (Ana IN absolute)
Config� channel 7
2000 07
0x02 (Bin OUT + read
back input)
Config� channel 8
2000 08
0x02 (Bin OUT + read
back input)
Config� channel 9
2000 09
0x01 (Bin IN)
Config� channel 10
2000 0A
0x01 (Bin IN)
Config� channel 11
2000 0B
0x01 (Bin IN)
Config� channel 12
2000 0C
0x01 (Bin IN)
Config� channel 13
2000 0D
0x03 (Ana IN absolute)
Config� channel 14
2000 0E
0x03 (Ana IN absolute)
Config� channel 15
2000 0F
0x02 (Bin OUT + read
back input)
Config� channel 16
2000 10
0x02 (Bin OUT + read
back input)
PWM frequency
2001 00
0x64 (100 Hz)
adjustable
after PreOp
Node ID *
20F0, 20F1
0x20 (0d32)
yes
after a reset
Baud rate *
20F2, 20F3
0x04 (125 Kbit/s)
yes
after a reset
Autostart
20F4
0x00 (Off)
adjustable
immediately
*) Observe rotary switch position!
Entries in the object directory indexes 20F0/20F1 and/or 20F2/20F3 are only valid
if the rotary switches for baud rate and/or node ID are in the position “F”�
Position and coding of the rotary switches → 7 Technical data