UK
CabinetModule CR2014
25
Index S-Idx Name
Type
Default
Description
20F0
0
CANopen node
ID
rw
u8
0x20
1���127
20F1
0
CANopen node
ID
rw
u8
0x20
The entries 20F0/20F1 must always
contain identical values�
The new entries are valid after a reset
(switching the module off/on)�
Values outside the permissible ranges
will be rejected�
20F2
0
CAN baud rate
rw
u8
0x03
0 = 1000 Kbaud
1 = 500 Kbaud
2 = 250 Kbaud
3 = 125 Kbaud
4 = 100 Kbaud
5 = 50 Kbaud
6 = 20 Kbaud
20F3
0
CAN baud rate
rw
u8
0x03
The entries 20F2/20F3 must always
contain identical values�
The new entries are valid after a reset
(switching the module off/on)�
Values outside the permissible ranges
will be rejected�
20F4
0
auto start
rw
u16
0x00
Time after reaching Preoperational
State to change to Operational State�
0���5000 ms
0 = auto start deactivated
2500
0
number of 8bit
user variables
ro
u8
0x0A
Idx 2500���2530 = range which can be
freely used for costumer specific entries
1
8bit user
variable 1
rw
u8
2
8bit user
variable 2
rw
u8
3
8bit user
variable 3
rw
u8
4
8bit user
variable 4
rw
u8
5
8bit user
variable 5
rw
u8
6
8bit user
variable 6
rw
u8
7
8bit user
variable 7
rw
u8
8
8bit user
variable 8
rw
u8
9
8bit user
variable 9
rw
u8
A
8bit user
variable 10
rw
u8