Safe Use Instructions
Before using the ethanol burner for the first time, make sure the following:
▪ Remove all the packaging material, the stickers and the labels.
▪ Check the contents of the packaging for any possible damage and make sure that all the parts are enclosed. Do not use
the burner if you realize any damage at the given parts.
▪ Make sure that you keep away all the packaging material from children. There is danger of accident or swallowing parts.
To assemble the burner place the quenching shutter at the connectors of the burner lid. The burner is now ready for use.
Filling the burner with fuel
▪ To fill the burner with fuel, firstly you always draw the shutter to its final position and then open the special filling hole.
ATTENTION:
Never fill the burner from its main opening cause there might be small hearths , non visible.
▪ Always fill the burner using the special devices to control the flow (e.g. funnel - See the Photo 4&5 - Page 9)
▪ Do not spill fuel out of the hole of the burner, there is serious danger of combustion. In case that fuel is spoilt, wipe
carefully all the surfaces.
ATTENTION:
Τhe fuel can destroy some surfaces (as wood, paint or skin).
▪ The burner is completely filled when the level of the fuel, during the filling, has reached the upper surface of the ceramic
stone. (The filling is realized in 2 parts. During the first filling, as soon as the fuel has reached the upper surface of the
stone, stop for 10-15’’, letting it absorb a part of the existent fuel. By the passage of the 10-15’’, when the fuel level has
been a little lessened, repeat the same procedure till the fuel level reaches again the upper surface of the stone.
Now the burner is completely filled.
▪ The burner doesn’t require the maximum fill with fuel for the correct function but works better when it is full.
▪ Especially for the first use the burner must be filled completely and slowly.
▪ Do not store the fuel close to the burner. Use safety distance, one meter at least.
▪ Use
only
fuel with main substance the ethanol. Fuels of different type are forbidden and constitute threat if used with
burner of this type.
Photo 1: Signs of Burner Safety
ATTENTION: Do not smoke during filling the burner with fuel and for as long as you handle the fuel.
Ignition
The burner is ready for ignition after having been filled with fuel.
▪ Draw the shutter to the open position.
▪ Use a suitable long lighter for the ignition of the burner’s surface.
▪ Do not put your hands on the surface of the fuel and do not stand over the burner while you turn it on. The ignition of
the burner must be done from the side and no parts of the body or flammable material should be over it.
▪ Do not blow towards the burner during the ignition there is danger of burn.
▪ The burner during the ignition does not produce the highest flame from the beginning. The highest flame result
(temperature and flame height) comes after 10-15 minutes of operation.
▪ Adjust the flame’s height, with the provided tool, drawing suitably the shutter from the open position.
▪ Avoid long periods of non use of the burner while the fuel is volatile and will be vaporized. If you intend not using it for a
long period of time, empty the fuel.
ATTENTION!
The burner must get cold in environment’s temperature before its
reignition.
Do not fire and do not fill the burner while being in warm condition.
Always check that the burner is completely off.
Quenching
▪ Do not turn off the burner using water, there is danger to explode.
▪ To turn off the burner use the provided tool (See Photos 5&6 - Pages 9-10) with which you will move the shutter till its
closed position. Leave the shutter on this position for at least five (5) minutes of the hour, to make sure that the burner’s
flame is completely off.
4
BIO BURN TYPE
DIMENSIONS
(WxLxH)
(cm)
FUEL CAPACITY
(mL)
NET
WEIGHT
(Kg)
ΑUTONOM
Y (h)
MINIMUM
ROOM DIMEN-
SIONS (m
2
)
BIO BURN CRM 43
43 Χ 19 Χ 8
1.950
8.0
3.5 – 5.0
12.5
BIO BURN CRM 58
58 Χ 19 Χ 8
2.600
11.0
3.5 – 5.0
15
BIO BURN CRM 75
75 Χ 19 Χ 8,3
3.400
18.0
3.5 – 5.0
21
BIO BURN CRM 93
93 Χ 19 Χ 8,3
4.200
22.5
4.0 – 6.0
35
BIO BURN CRM 113
113 Χ 22 Χ 13,0
10.500
40.0
6.0 – 8.0
50
BIO BURN CRM 130
130 Χ 22 Χ 13,0
14.000
56.0
6.0 – 8.0
75