6.2 RS-422 Communication Port Connection
6.2.1 RS-422 Connection (Single iCON100 Connection)
An RS422/RS232 converter is required to use RS422 communication between the
iCON100
and the PC.
CAUTION:
The INC400 converter is recommended for stable communication when the distance between
the converter and the device is too far.
Please follow the instructions below;
- Connect RS422-TX (+) (Gray wire) of iCON100 to RS422-RX (+) port of converter.
- Connect RS422-TX (-) (Yellow wire) of iCON100 to RS422-RX (-) port of converter.
- Connect RS422-RX (+) (Brown wire) of iCON100 to RS422-TX (+) port of converter.
- Connect RS422-RX (-) (Blue wire) of iCON100 to RS422-TX (-) port of converter.
- Plug in the RS232 9PIN connector of the converter to the COM n port of the PC.
- Install and run iCON100 Application Software.
Figure: RS422 Communication between
iCON100