iCON100/iCON100-SR QUICK INSTALLATION GUIDE
10
5. INSTALLATION OF THE PRODUCT
5.1 Dimension (Unit: inch (mm))
Figure: iCON100 Dimension Figure: LCD Module Dimension
Figure: Keypad Dimension
5.2 System Initialization of iCON100
Initialization must be performed before first installation of iCON100. Press down the two initialization switches
simultaneously then keep pressing more than 2 seconds. Once buzzer sound is generated, release the
switches then initialization is done and system restarts automatically
.
Figure: Switches Location Figure: Magnification of Switches Figure: LCD Display
Caution
If you initialize the iCON100, all data such as user ID, baud rate, door setting, time schedule and event
information stored in the controller will be cleared and the default values (factory setting values) will be
reloaded. Therefore, the Initialization should be performed by authorized person only. It is recommended to
upload all events data before initialization in case you use events data for time and attendance purpose.
PRESS
SYSTEM INIT.
WAITING !!!
3.1(77)
1.4
(3
4)
7.9(200)
3.1(77)
3.1
(7
7
)
5.4
(1
37
)
5.4(137)
'