HOWTO1

 

How to check if the internal data of the device is damaged.

 

(Procedure Based on FINGER007)

 

Internal  data  refers  to  the  data  stored  in  the  device,  including  the  Card  Holder  data  (IDs, 

passwords,  fingerprint  data),  Time  Schedule  (T/S),  Input/Output  settings  (IN/OUT  Define),  etc. 

These settings and data are retained in the memory of the device, but if the backup battery gets 

discharged  or  if  the  backup  battery  is  switched  off  or  if  the  device  is  affected  by  noise,  the 

internal  data  can  get  damaged  and  changed  to  other  values.  The  following  will  explain  how  to 

enter the SETUP MENU (also called Master Mode) on a device that has an LCD screen and check 

internal settings and data. 

 

1. 

From the stand-by mode, enter the 8-digit Master ID number 

and  press                to  enter  the  SETUP  MODE.  (The  default 

Master  ID  is  “00000000”.  For  some  models,  it  is 

“0000000000”.) 

 

2. 

After the “Master Password” screen appears, enter the Master 

Password. (The default password is “3141”.) 

 

 

3. 

The  “Mode  Selection  (Reader  Mode1)”  screen  appears. 

You’ve now entered the SETUP MODE and you can check the 

internal data and setting values.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. 

After  you’re  done  with  the  confirmation,  press              to  quit 

the SETUP MENU. 

 

 

 

MODE SELECTION 

RF ONLY 

FINGER_007    [F1] 

MM/DD   hh:mm:ss 

Master   Password 

[ _ _ _ _ ] 

FINGER_007    [F1] 

MM/DD   hh:mm:ss 

ENT

ESC 

Function keys, from 

 

F1 

  to 

 

F4

, are for entering F1 SETUP MENU to F4 SETUP MENU, and 

the  navigation  keys, 

 

  and 

 

,  are  for  moving  to  different  submenus  or  for  selecting 

different  items. 

 

ENT 

  is  used  to  change  specific  settings  or  to  apply  changed  settings,  and 

 

ESC 

  is used to cancel settings or to return to the previous menu.   

Confirm if the internal data such as stored Card Holder information (IDs, passwords, fingerprint 

data),  Time  Schedule  (T/S),  Input/Output  Settings  (IN/OUT  DEFINE)  are  the  way  they  were 

configured last time. 

Содержание FINGER007 Series

Страница 1: ......

Страница 2: ... discharge b During installation you have to connect the Battery Jumper as shown in Figure 2 so that the Controller can retain data in the event of power failure Figure 1 Battery Jumper location Figure 2 2 Initialization If an LCD module is connected to the iTDC a Apply DC power to the Controller and press the two INT Switches simultaneously Figure 3 b The LCD will display Initialized OK Turn OFF ...

Страница 3: ...hen power off the Controller and return the DIP SW 8 to the ON position Then power on the Controller again Figure7 2 FINGER006 007 Series 505 Series FACE006 007 Series 1 Battery Switch Setting Turn on the backup battery switch as shown below 2 Initialization Hard Initialization 1 Power off the product and connect the yellow and cyan wires of the product to the GND Turn on the power See the diagram...

Страница 4: ...r the password The default password 3141 3 The Mode Selection or READER 1 MODE screen appears 4 Press or until the LCD displays SYS INITIALIZE When it does press 5 Press and the System Initializing message will appear The system is being initialized NOTE All stored data will be lost after initialization 6 After the initialization is completed the LCD displays the SYS INITIALIZE message 7 Use to qu...

Страница 5: ...itted signal will stabilize 18 6us after the leading edge of a bit Since the data bit is captured in the middle of the bit which is approximately 52us after the leading edge of a bit The reflection stabilizing time 18 6us is much before the center of the bit therefore the termination resistors are not required However if you install the cable to maximum length the impedance of cable and network is...

Страница 6: ...hen the voltage level of both ends of shield wire is not equal and this current flow will create noise and interfere to communications For the good grounding we recommend to connecting ONLY one end of shield wire of communication cable to grounding system If you find earth ground nearby then connect one end of shield wire to earth ground If you do not have earth ground nearby then find chassis gro...

Страница 7: ...ter the Password PW Time Schedule TS Reader to be assigned RD and Use of Fingerprint FP Enter appropriate values For fingerprint registration enter 1 in the FP field 8 After the To Register FP Put your FP on message appears and the fingerprint sensor is lit place the finger you d like to register on the fingerprint sensor 9 If the Lift and Put FP message appears lift your finger up and wait until ...

Страница 8: ...r ID is 00000000 For some models it is 0000000000 2 After the Master Password screen appears enter the Master Password The default password is 3141 3 The Mode Selection Reader Mode1 screen appears You ve now entered the SETUP MODE and you can check the internal data and setting values 4 After you re done with the confirmation press to quit the SETUP MENU MODE SELECTION RF ONLY FINGER_007 F1 MM DD ...

Страница 9: ...hen press to move to the F3 SETUP MENU 4 The ID REGISTRATION screen appears 5 Press twice then the ID LIST screen will appear 6 Press then you can check the list of the IDs registered in the device If there s no ID registered the MEMORY EMPTY appears 7 If there is more than one ID registered information such as the ID number password assigned Time Schedule assigned reader number use of fingerprint...

Отзывы: