HELP1

 

Switch on the backup battery, and initialize the device. 

There is a switch for a backup battery inside the device. In order to prevent the backup battery 

from being discharged, the switch for the backup battery is open (

i.e.

 turned off) at the time of 

shipment. To use the device, however, the switch must be turned on, so that the data recorded 

in  RAM  memory  can  be  kept  over  time.  Follow  the  instructions  below,  according  to  the  model 

that you are using. 

   

1.

 iTDC Series, iCON Series 

1) Backup Battery Switch Setting 

a.

 

The Battery Jumper is originally left disconnected as shown in <Figure 1> to prevent battery discharge. 

b.

 

During  installation,  you  have  to  connect  the  Battery  Jumper  as  shown  in  <Figure  2>,  so  that  the 

Controller can retain data in the event of power failure. 

 
 
 
 

 
 

 

 

  <Figure 1>       

                        Battery Jumper location                                                <Figure 2> 

 

 

2) Initialization 

 

If an LCD module is connected to the iTDC, 

a.

 

Apply DC power to the Controller and press the two INT Switches simultaneously. <Figure 3> 

b.

 

The LCD will display “Initialized OK Turn OFF Power…”. <Figure 4> 

c.

 

Power OFF and ON again. The Controller is now ready to work.   

 

 

 

 

 

 

INT Switch Location                              <Figure 3> INT Switches                              <Figure 4> LCD Message 

 
 

If an LCD module is NOT connected to the iTDC, 

a.

 

Apply DC power to the Controller and press the two INT Switches simultaneously. <Figure 3> 

b.

 

Power OFF the controller and wait for about 2 seconds. Then, power ON the controller again. 

 

 

 

 

PRESS 

Initialized OK 
Turn OFF Power…

 

Содержание FINGER007 Series

Страница 1: ......

Страница 2: ... discharge b During installation you have to connect the Battery Jumper as shown in Figure 2 so that the Controller can retain data in the event of power failure Figure 1 Battery Jumper location Figure 2 2 Initialization If an LCD module is connected to the iTDC a Apply DC power to the Controller and press the two INT Switches simultaneously Figure 3 b The LCD will display Initialized OK Turn OFF ...

Страница 3: ...hen power off the Controller and return the DIP SW 8 to the ON position Then power on the Controller again Figure7 2 FINGER006 007 Series 505 Series FACE006 007 Series 1 Battery Switch Setting Turn on the backup battery switch as shown below 2 Initialization Hard Initialization 1 Power off the product and connect the yellow and cyan wires of the product to the GND Turn on the power See the diagram...

Страница 4: ...r the password The default password 3141 3 The Mode Selection or READER 1 MODE screen appears 4 Press or until the LCD displays SYS INITIALIZE When it does press 5 Press and the System Initializing message will appear The system is being initialized NOTE All stored data will be lost after initialization 6 After the initialization is completed the LCD displays the SYS INITIALIZE message 7 Use to qu...

Страница 5: ...itted signal will stabilize 18 6us after the leading edge of a bit Since the data bit is captured in the middle of the bit which is approximately 52us after the leading edge of a bit The reflection stabilizing time 18 6us is much before the center of the bit therefore the termination resistors are not required However if you install the cable to maximum length the impedance of cable and network is...

Страница 6: ...hen the voltage level of both ends of shield wire is not equal and this current flow will create noise and interfere to communications For the good grounding we recommend to connecting ONLY one end of shield wire of communication cable to grounding system If you find earth ground nearby then connect one end of shield wire to earth ground If you do not have earth ground nearby then find chassis gro...

Страница 7: ...ter the Password PW Time Schedule TS Reader to be assigned RD and Use of Fingerprint FP Enter appropriate values For fingerprint registration enter 1 in the FP field 8 After the To Register FP Put your FP on message appears and the fingerprint sensor is lit place the finger you d like to register on the fingerprint sensor 9 If the Lift and Put FP message appears lift your finger up and wait until ...

Страница 8: ...r ID is 00000000 For some models it is 0000000000 2 After the Master Password screen appears enter the Master Password The default password is 3141 3 The Mode Selection Reader Mode1 screen appears You ve now entered the SETUP MODE and you can check the internal data and setting values 4 After you re done with the confirmation press to quit the SETUP MENU MODE SELECTION RF ONLY FINGER_007 F1 MM DD ...

Страница 9: ...hen press to move to the F3 SETUP MENU 4 The ID REGISTRATION screen appears 5 Press twice then the ID LIST screen will appear 6 Press then you can check the list of the IDs registered in the device If there s no ID registered the MEMORY EMPTY appears 7 If there is more than one ID registered information such as the ID number password assigned Time Schedule assigned reader number use of fingerprint...

Отзывы: