IDS 1632 Installer Manual 700-256-02K Issued September 2009
48
Siren Toot on Away Arm / Disarm:
This option allows the user an audible confirmation that arming or disarming of the panel has occurred.
The siren can be programmed to give a short beep after successful arming, and two short beeps after
disarming. This is useful when used in conjunction remote or key-switch arming/disarming.
Engineer Reset:
If enabled this option prevents arming the panel after an alarm condition has occurred. The panel can
only be armed after the engineer has entered a valid installer code. A trouble condition will be displayed
on the keypad if enabled in location 40.
Sub-location 5
Partition Options
LED ON / OFF
Action
1
ON
Enable Automatic Re-enabling of Shutdown Zones at the Time of the
Dialler test.
OFF
Disable Automatic Re-enabling of Shutdown Zones at the Time of the
Dialler test.
2
ON
Enable Bypassing of Common Zones
OFF
Disable Bypassing of Common Zones
3
ON
Enable Delay Before Communications
OFF
Disable Delay Before Communications
4
ON
Enable Keypad Lockout
OFF
Disable Keypad Lockout
5
ON
Enable User Phone Access
OFF
Disable User Phone Access
6
ON
Enable Silent Keypad Panic
OFF
Disable Silent Keypad Panics
Sub-location 6
Exit Delay Period
Value
Time-out Delay
Value Time-out Delay
0
3 Seconds
8
2 Minutes
1
10 Seconds
9
3 Minutes
2
15 Seconds
10
4 Minutes
3
20 Seconds
11
5 Minutes
4
25 Seconds
12
10 Minutes
5
30 Seconds (default)
13
15 Minutes
6
45 Seconds
14
18 Minutes
7
1 Minute
15
21 Minutes
The exit delay will begin after the entry of a valid user code (or pressing of the
[1]
or
[6]
, initiating the
quick-arm function). During this period, it is permissible to violate entry/exit and follower zones without
causing an alarm condition thus allowing exit from the premises.
Select the appropriate exit delay period from the table above. If an instant zone is violated
during this period, an alarm condition will immediately be registered. Select the appropriate value for the
primary exit delay from the table.
Sub-location 7
Primary Entry Delay Time
(Values identical to Sub-location 6) This entry delay begins after the violation of a primary entry/exit zone.
During this period, it is permissible to violate follower zones without causing an alarm condition provided
that an entry/exit zone was violated first.
Содержание 1632
Страница 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Страница 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Страница 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Страница 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Страница 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...