IDS 1632 Installer Manual 700-256-02K Issued September 2009
17
Table 1 : Values Represented by each Zone LED
Zone LED Value Digit Zone LED Value
Digit
Zone 1
1
Units
Zone 9
1
Hundreds
Zone 2
2
Zone 10
2
Zone 3
4
Zone 11
4
Zone 4
8
Zone 12
8
Zone 5
1
Tens
Zone 13
1
Thousands
Zone 6
2
Zone 14
2
Zone 7
4
Zone 15
4
Zone 8
8
Zone 16
8
Example:
Assume the following zone indicators are on:
Zone 1, Zone 3 and Zone 5.
Units are represented by the sum of Zone 1 and Zone 3 (i.e. 1 + 4) and tens of units are represented by
the value of Zone 5 (i.e. 1)
Thus, the value indicated by the lit LED will be shown below.
Zone LED Value Digit
Zone 1
1
Units
Zone 2
2
Zone 3
4
Zone 4
4
Zone 5
1
Tens
Zone 6
2
Zone 7
4
Zone 8
8
Therefore, the displayed value is 15.
7. Programming the Panel
For all programming procedures, the
[*]
star key functions as the
<ENTER>
key and the
[#]
hash key
functions as a
<CLEAR>
or an
<EXIT>
program key.
Invalid data entries are indicated by means of an error beep consisting of 3 short beeps of the
keypad buzzer.
There are two location categories:
Standard locations which are single tiered and do not contain any sub-locations.
Extended locations that are double tiered and have sub-locations.
Both standard and extended locations may contain further subcategories referred to as bitmapped
locations.
For both main categories, clear visual keypad prompts are provided which aid the
programming process.
Содержание 1632
Страница 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Страница 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Страница 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Страница 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Страница 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...