IDS 1632 Installer Manual 700-256-02K Issued September 2009
22
5
ARM / DISARM ZONE
The violation of an Arm/ Disarm zone will cause the panel to toggle between (away) armed and
disarmed. It is typical to connect a momentary key-switch, or non-latching remote control unit to
this zone.
9
RESERVED
10
FIRE ZONE
Violation of a Fire Zone will cause the siren to sound regardless of whether the panel is armed
or not. The siren will sound intermittently (one second on, one second off) For correct operation
a programmable output programmed as a fire detector power output must be used to control
power to the fire detector.
11
TAMPER ZONE
Violation of this zone will be reported to the base station regardless of whether the panel is
armed or disarmed. If the panel is armed, the siren will be activated.
12
24 HOUR ALARM ZONE
This works the same as a panic zone – with the exception that it is able to be bypassed.
13
WARNING ZONE
When the panel is armed, violation of a warning zone will cause the siren to beep. The violation
is logged in the event log but it is not reported to the base station. Warning zones may be
included and will be counted when used as part of the cross-zone matrix.
14
PUSH TO ARM ZONE
Violation of a push to arm zone during the exit delay will immediately arm the panel.
15
OUTDOOR INSTANT ZONE
When the panel is armed violation of an outdoor instant zone will cause the panel to register an
alarm condition.
Sub-location 2
Zone Properties (Defaults Shaded)
Bitmapped location – select all properties for Zone
LED ON / OFF
Zone Properties
1
ON
Tamper by Zone Enabled
OFF
Tamper by Zone Disabled
2
ON
Cross-Zone Enabled
OFF
Cross-Zone Disabled
3
ON
Shutdown Zone Enabled
OFF
Shutdown Zone Disabled
4
ON
Silent Zone Enabled
OFF
Silent Zone Disabled
5
ON
Second Loop Response Enabled
OFF
Second Loop Response Disabled
Further zone related functionality explained
Tamper by Zone
Individual zones may be enabled for tamper by zone. For connection details, see Figure 2. This feature is
not available if zone doubling is enabled. (See Figure 3, page 12 and Location 38, page 26)
Cross-Zoning
This feature is useful for reducing false alarms. Violating zones with the cross-zone property enabled will
not immediately generate an alarm. The Cross-Zone Delay Timer is started. See Location 36.
Depending on the value programmed into location 37 (Cross-Zone Trip Count), the zone (or
any other zone with cross-zone option enabled) must trip the number of times programmed into location
Содержание 1632
Страница 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Страница 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Страница 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Страница 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Страница 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...