IDS 1632 Installer Manual 700-256-02K Issued September 2009
38
LOCATION 116
Primary Communicator Format
Value
Format Name
Description
0
Ademco Express
Dual Tone HS, DTMF
1
FBI 4 x 2 ( With Parity)
1.8kHz TX, 2.3kHz HS, 40PPS
2
FBI 4 x 2 (No Parity)
1.8kHz TX, 2.3kHz HS, 20PPS
3
Silent Knight 4 x 2 Fast
1.9kHz TX, 1.4kHz, 20PPS
4
Silent Knight 4 x 2 Slow 1.9kHz TX, 1.4kHz, 20PPS
5 (Default) Contact ID
Dual Tone HS, DTMF
6
Domestic Reporting
1.8kHz TX, Blind, 20PPS
7
SIA Reporting
Bell 103 FSK, HS
8
SMS/GSM Reporting
Sends SMS to prescribed Nos.
9
Voice Reporting**
Reports to prescribed numbers
TX
= Transmit
HS
= Handshake
PPS
= Pulses per Second
The value entered into location 116 selects the primary communicator format. Select from the table above
the value appropriate to the required format. During communication, the green LED on the PCB will come
one indicating that the panel has taken the telephone off-hook. If programmed accordingly (see location
38), the keypad will beep after receiving a handshake from the base station. This indicates a successful
transmission of data.
Notes on Voice Reporting
Voice reporting works automatically with DTMF dialling once a Voice Module is installed on the Panel.
The voice tells the user what has happened on the panel.
For events that cause a voice report, the Panel will call the relevant number. Six seconds after it has
dialled the last digit, it will begin speaking out its report, speaking each event three times. After all events
are spoken out three times, it hangs up. This identical call is made the number of times stored in Location
115.
The user may terminate the report for the current event by entering their user code (if enabled
in loc 128/129 sub loc 5 bit 5) and then hanging up by pressing #. The call will end and the Panel will not
call again until another reportable event occurs.
Stop report and control the Alarm Panel
If the user enters a valid code during the voice report, the voice report is halted and a DTMF-driven menu
system, with voice prompting, is available by which the user may control the Alarm Panel.
The user may access this control menu by dialling the number of the phone line that the Alarm
Panel wired to (if enabled).
LOCATION 117
Secondary Communicator Format
If dual reporting is enabled then this format will be used to report to phone number 2. (See the same
Table for location 116.)
NOTES ON DUAL REPORTING
When dual reporting is enabled, it is possible to select two different formats. In this instance all data will
be transmitted to each phone number (i.e. reported twice) using a different format per phone number.
Содержание 1632
Страница 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Страница 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Страница 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Страница 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Страница 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...