English
20
e.
Rotate the knob 1 (fig.01) to (DO NOT ROTATE TO
), then toggle the cleaning program
switch to “ON” 14 (fig.11). When the descaling product begins to flow through the steam hose rotate
the knob 1 (fig.01) and toggle the cleaning program switch to the OFF position
.
f.
Wait approximately two hours and repeat the drainage procedure as described in section 12b. Dispose of
the cleaning product properly; do not spill it near soil, water sources or sewers.
g.
To make sure that there is no descaling residue left in the machine’s pipes, rinse it with running water.
Fill it and follow the instructions in section 12e. Subsequently empty the boiler as described in section
12b.
h.
Screw the steam gun to the hose, position the rubber protection and close the steam outlet by pressing
the relative button on the main panel. Replace the machine’s protective cover and replace the
placeholder screw 12 (fig.09). Follow the steps in section 8e to store the machine properly.
13.
MAINTENANCE FOR STEAM – CLEANING THE BOILER SENSORS
Figure 09
Figure 12
a.
Put the Steamer in STANDBY mode (rotating the knob to OFF
and then ON ). Pull the trigger on the
steam gun and make sure the steam outlet is open.
b.
After the machine has cooled down remove the protective cover after having unscrewed the placeholder
screw 12 (fig.09)
c.
Disconnect the sensors by removing the connectors 15 (fig.12) and unscrewing the nut 16 (fig.12)
d.
Unscrew the 3 sensors with a 22mm wrench (see fig.12)
12
16
15