manualshive.com logo in svg
background image

 

iPOINT  – Hardware User Manual | 18.06.2020 

 

Copyright © 2020  IDENTEC SOLUTIONS. All rights reserved. 
 

5

 

Safety Instructions 

The equipment can be installed in restricted areas. 
The system described in this manual is for exclusive operation of trained employees. Only qualified personnel that 
have knowledge of the potential dangers involved should perform the installation, settings, maintenance and repair 
of the units used. 
 

Operational Safety 

The correct and safe use of these systems assumes that operating and service personnel follow the safety 
measures described in the manual alongside the generally acceptable safety procedures. 
If there is a possibility that safe operations cannot be guaranteed, the system must be switched off, secured against 
accidental use and the service unit responsible immediately informed. 
 

Safety Documents 

The iPOINT was designed, tested and supplied in perfect condition, according to document IEC/EN 60950-1 Safety 
Requirements. 
 

Condensate / Change of Temperature 

To avoid condensation in the system, the unit must be allowed to slowly adjust itself to warmer temperatures after 
removal from cold and cool environments.  
 

Do not open the Main housing 

The Connection Chamber can be opened for required cabling needs, but there is no need to open the main 
housing (crews from bottom side) in order to set the iPOINT unit. The unit does not have any internal setting 
elements or displays.  
 

Connections / Power Supply 

The supply circuits must comply with the conditions set out for the SELV circuits (see EN 60950-1). 
The signal circuits must comply with the conditions set out for the SELV circuits (see EN 60950-1). 
Use shielded cables for the Ethernet/PoE & RS422 cables. This is the only way to achieve the prescribed EMC. 
During maintenance damage could occur if printed circuit boards or cables are connected or disconnected whilst 
the power supply is still on. Therefore, only work on the connection and the components when they are not live. 

 

Spare Parts 

We recommend that only personnel, original products, spare and replacement parts authorized by IDENTEC 
SOLUTIONS be used for installation, service and repair. IDENTEC SOLUTIONS does not accept any responsibility 
for materials used, work carried out or possible consequences from unauthorized third party vendors. 
 

Glossary 

 

SELV 

Safety Extra Low Voltage – Protective measure against dangerous body currents. Protective first voltage, circuit not floating. 

 

EMC 

Electromagnetic Compatibility

 

 

 

Содержание iPOINT Si

Страница 1: ...IDENTEC SOLUTIONS Model IDS1001 iPOINT Si HARDWARE USER MANUAL...

Страница 2: ...y person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or reven...

Страница 3: ...nded This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Conformit l exposition aux champs RF des quipements radio Pour satisfaire aux exigences F...

Страница 4: ...crew on the unit Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit Avoid unnecessary contact with the unit connectors and assemblies inside t...

Страница 5: ...d cool environments Do not open the Main housing The Connection Chamber can be opened for required cabling needs but there is no need to open the main housing crews from bottom side in order to set th...

Страница 6: ...SB Connector Pinout 15 2 4 USB Only mode Function and specification 16 2 5 Communication Interface Priorities 16 2 6 Lid Open Detection 16 3 Initial Operation Configuration 17 3 1 Status LEDs 17 4 Mec...

Страница 7: ...the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided upo...

Страница 8: ...e Housing contains 5 Status LEDs see Section 3 1 a Connection Chamber where the wired interfaces can be accessed Relevant cable glands as wired access points depending on the device setup Mounting Pla...

Страница 9: ...cols The iPOINT X has two internal UHF antennas built in and can communicate up to a range of 500 meters with its Tags The main benefit of two antennas is the elimination of RF dead spots in static sy...

Страница 10: ...reserved 10 2 1 3 NFC Interface The NFC Interface is a Near Field Communication interface The iPOINT can be used as an entry terminal or for other NFC communication The range to the Tag is around 10 1...

Страница 11: ...racking and Tracing Localization Environmental Data Sensing i B350 Tags IDENTEC SOLUTIONS i B350 tags are designed to be cost effective and easy to implement while offering maximum flexibility The bea...

Страница 12: ...or for debugging low power operation and device configuration RS422 MASTER RJ45 RS422 cable connector to the host computer or previous Slave port in the daisychain RS422 SLAVE RJ45 RS422 cable connect...

Страница 13: ...d 13 RS422 with injected 24V Power installation Make sure power supply can handle all iPOINTs in the system USB Mode 5V Local USB mode over Mini USB Connector for debugging low power operation and Con...

Страница 14: ...units in the chain must not exceed 1000 m 3200 ft The distance from one unit to the next must not exceed 300 m 1000 ft This table is valid for Cat 5 cabling with gauge diameters of AWG24 0 25 mm of i...

Страница 15: ...r bus 8 GND GND Brown Power supply over bus As the TxD RxD crossing is done by the pinout of the connectors simple straight cabling has to be used Connection parameters Signal levels RS422 Baud rate 1...

Страница 16: ...ver TBD Enter config debugging info 2 5 Communication Interface Priorities The priorities for the wired connections will be 1 USB Highest priority A connection over USB will terminate all other existi...

Страница 17: ...Orange when a response or a broadcast is received LF This is the LF Communication LED LED blinks green when Marker Loop ID is sent It blinks red if LF is not working properly e g loop broken or loop...

Страница 18: ...from the front side until magnetic connection is released lift off 2 Loosen the 8x screws be aware DO NOT pull out the screws out completely the gasket can be damaged 3 Lift off the lid 4 Now you hav...

Страница 19: ...ting plate only 4x countersunk screws are required with a maximum diameter of 5mm or M5 screws Length and type shall be chosen depending on wall material 4x countersunk screws Choose screw type and le...

Страница 20: ...here s a risk of damage 4 2 1 Optional Extra Pole Mount Bracket Kit A Pole Mount Bracket Kit is available Pole Mount Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to...

Страница 21: ...xtension Bracket Kit is available Extension Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o Multiple mou...

Страница 22: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 22...

Страница 23: ...epends on the relevant system concept and very likely varies from one system to another A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors sec...

Страница 24: ...order to keep down times short it is recommended that these parameters are set before the component is entered into the spare part stock system In most cases all units within an identification system...

Страница 25: ...Interface USB USB Mini Status Display 5 LEDs UHF LF COM RUN NFC Electrical Power Source PoE 12 30VDC RS422 Master Power Consumption according to 802 3af3 Max 7 Watt Environmental Conditions Operating...

Страница 26: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 26...

Отзывы: