manualshive.com logo in svg
background image

 

iPOINT  – Hardware User Manual | 18.06.2020 

 

Copyright © 2020  IDENTEC SOLUTIONS. All rights reserved. 
 

3

 

Radio Frequency Compliance Statement 

 
IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: 
 

MODEL: 

 

IDS1001 iPOINT  Si 

Region/Country 

Organization 

Marking 

EUROPE: 

EU 

CE 

USA: 

FCC 

FCC ID OO4-IDS1001 

CANADA: 

IC 

3538A-IDS1001 

 
The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by 
IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC 
SOLUTIONS, or unauthorized changes to approved products, may void the compliance of these products and result in 
the loss of the user(s) authority to operate the equipment. 
 

European Declaration of Conformity according to RED Directive 

 
IDENTEC SOLUTIONS AG hereby declares that the device iPOINT is in conformity with the essential requirements 
of Directive 2014/53/EU. The declaration of conformity can be found at: 

www.identecsolutions.com

 

 

Radio Frequency (RF) Exposure Compliance of Radio Communication Apparatus 

To satisfy FCC and ISED RF Exposure requirements for mobile devices, a separation distance of 20 cm or more should be 
maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than 
this distance is not recommended. This transmitter must not be co-located or operating in conjunction with any other antenna 
or transmitter. 
 

Conformité à l’exposition aux champs RF des équipements radio  

Pour satisfaire aux exigences FCC et ISED concernant l'exposition aux champs RF pour les appareils mobile, une distance 
de séparation de 20 cm ou plus doit être maintenu entre l'antenne de ce dispositif et les personnes pendant le 
fonctionnement. Pour assurer la conformité, il est déconseillé d'utiliser cet équipement à une distance inférieure. Cet émetteur 
ne doit pas être co-situé ou fonctionner conjointement avec une autre antenne ou un autre émetteur. 
 

Canada Certification 

Licence-Exempt Radio Apparatus (ISED) 
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic 
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 
1.This device may not cause interference. 
2.This device must accept any interference, including interference that may cause undesired operation of the device. 
 
Appareils radio exempts de licence (ISDE) 
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, 
Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est 
autorisée aux deux conditions suivantes : 
1.L’appareil ne doit pas produire de brouillage; 
2.L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre 
le fonctionnement. 

 

 

 

Содержание iPOINT Si

Страница 1: ...IDENTEC SOLUTIONS Model IDS1001 iPOINT Si HARDWARE USER MANUAL...

Страница 2: ...y person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or reven...

Страница 3: ...nded This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Conformit l exposition aux champs RF des quipements radio Pour satisfaire aux exigences F...

Страница 4: ...crew on the unit Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit Avoid unnecessary contact with the unit connectors and assemblies inside t...

Страница 5: ...d cool environments Do not open the Main housing The Connection Chamber can be opened for required cabling needs but there is no need to open the main housing crews from bottom side in order to set th...

Страница 6: ...SB Connector Pinout 15 2 4 USB Only mode Function and specification 16 2 5 Communication Interface Priorities 16 2 6 Lid Open Detection 16 3 Initial Operation Configuration 17 3 1 Status LEDs 17 4 Mec...

Страница 7: ...the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided upo...

Страница 8: ...e Housing contains 5 Status LEDs see Section 3 1 a Connection Chamber where the wired interfaces can be accessed Relevant cable glands as wired access points depending on the device setup Mounting Pla...

Страница 9: ...cols The iPOINT X has two internal UHF antennas built in and can communicate up to a range of 500 meters with its Tags The main benefit of two antennas is the elimination of RF dead spots in static sy...

Страница 10: ...reserved 10 2 1 3 NFC Interface The NFC Interface is a Near Field Communication interface The iPOINT can be used as an entry terminal or for other NFC communication The range to the Tag is around 10 1...

Страница 11: ...racking and Tracing Localization Environmental Data Sensing i B350 Tags IDENTEC SOLUTIONS i B350 tags are designed to be cost effective and easy to implement while offering maximum flexibility The bea...

Страница 12: ...or for debugging low power operation and device configuration RS422 MASTER RJ45 RS422 cable connector to the host computer or previous Slave port in the daisychain RS422 SLAVE RJ45 RS422 cable connect...

Страница 13: ...d 13 RS422 with injected 24V Power installation Make sure power supply can handle all iPOINTs in the system USB Mode 5V Local USB mode over Mini USB Connector for debugging low power operation and Con...

Страница 14: ...units in the chain must not exceed 1000 m 3200 ft The distance from one unit to the next must not exceed 300 m 1000 ft This table is valid for Cat 5 cabling with gauge diameters of AWG24 0 25 mm of i...

Страница 15: ...r bus 8 GND GND Brown Power supply over bus As the TxD RxD crossing is done by the pinout of the connectors simple straight cabling has to be used Connection parameters Signal levels RS422 Baud rate 1...

Страница 16: ...ver TBD Enter config debugging info 2 5 Communication Interface Priorities The priorities for the wired connections will be 1 USB Highest priority A connection over USB will terminate all other existi...

Страница 17: ...Orange when a response or a broadcast is received LF This is the LF Communication LED LED blinks green when Marker Loop ID is sent It blinks red if LF is not working properly e g loop broken or loop...

Страница 18: ...from the front side until magnetic connection is released lift off 2 Loosen the 8x screws be aware DO NOT pull out the screws out completely the gasket can be damaged 3 Lift off the lid 4 Now you hav...

Страница 19: ...ting plate only 4x countersunk screws are required with a maximum diameter of 5mm or M5 screws Length and type shall be chosen depending on wall material 4x countersunk screws Choose screw type and le...

Страница 20: ...here s a risk of damage 4 2 1 Optional Extra Pole Mount Bracket Kit A Pole Mount Bracket Kit is available Pole Mount Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to...

Страница 21: ...xtension Bracket Kit is available Extension Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o Multiple mou...

Страница 22: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 22...

Страница 23: ...epends on the relevant system concept and very likely varies from one system to another A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors sec...

Страница 24: ...order to keep down times short it is recommended that these parameters are set before the component is entered into the spare part stock system In most cases all units within an identification system...

Страница 25: ...Interface USB USB Mini Status Display 5 LEDs UHF LF COM RUN NFC Electrical Power Source PoE 12 30VDC RS422 Master Power Consumption according to 802 3af3 Max 7 Watt Environmental Conditions Operating...

Страница 26: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 26...

Отзывы: