7.  Technical Specifications 

Communication ILR

350 

technology

 

Operation Mode 

 

 

 

UHF Broadcast or response communication  

Read Range 

 

 

 

up to 500 m 

1

 

Compatibility 

 

 

 

i-B350, i-Q350, iQ355 Tags 

Operating Frequency 

 

 

 

UHF ISM Band: 868 MHz (EU) or 920 MHz (NA)

2

 

Antenna / Transmit Power 

 

 

 

2x Internal Antennas / <1mW 

 

 

 

 

 

Communication LF

boost

 Marker

 

Operation Mode 

 

 

 

Sends Marker ID at a predefined interval 

Exciter Range 

 

 

 

up to 5m

 

(adjustable)  

1

 

Compatibility 

 

 

 

LF

boost

 enabled tags 

Operating Frequency 

 

 

 

125kHz 

 

 

 

 

 

Communication NFC

 

 

 

 

 

Antenna 

 

 

 

Integrated 13.56MHz coil (read/write) 

Standards 

 

 

 

ISO/IEC 15693, ISO/IEC 14443A&B, Sony FeliCa 

Status Notification 

 

 

 

NFC detection notification via Buzzer and LED 

 

 

 

 

 

Performance 

 

 

 

 

Multiple Tag handling 

 

 

 

Up to 1000 ILR Tags per read zone 

Marker ID 

 

 

 

16bit programmable 

 

 

 

 

 

Interfaces

 

 

 

 

 

Data Interface Master/Host 

 

 

 

RS422 – RJ45 

Data Interface Slave 

 

 

 

RS422 – RJ45 

Data Interface PoE 

 

 

 

PoE – RJ45 

Data Interface USB 

 

 

 

USB Mini 

Status Display 

 

 

 

5 LEDs (UHF, LF, COM, RUN & NFC) 

 

 

 

 

 

Electrical 

 

 

 

 

Power Source 

 

 

 

PoE

 

12-30VDC (RS422 Master)

 

Power Consumption 

 

 

 

according to 802.3af3

 

Max. 7 Watt 

 

 

 

 

 

 

Environmental Conditions 

 

 

 

 

Operating Temperature 

 

 

 

-40°C to +70°C (-40°F to +158 °F) 

Storage Temperature 

 

 

 

-40°C to +85°C (-40°F to +185°F) 

Humidity 

 

 

 

Up to 50%, non-condensing (open), 100% (closed) 

Shock: 

 

 

 

EN 60068-2-32: Multiple drops to concrete from 1m (3ft), 5 times 
EN 60068-2-29: 50G on all 3 axis, 3 times per axis 

Vibrations 

 

 

 

EN 60068-2-64: noise 5 to 1000Hz, 90 minutes per axis 
EN 60068-2-6: 5G, 20 sin wave cycles per axis, 5-500Hz 

Standard/Certification 

 

 

 

 

Europe 

 

 

 

CE

 (EN 300 220-1, -2; EN 301 489-1,-3; EN 62368-1; EN 300 330; 

EN 50364; EN 62369-1; EN62311) 

North America 

 

 

 

FCC

 Part 15 (US); 

IC

 RSS210 

 
Mechanical Data 

 

 

 

 

Dimensions 

 

 

 

(L) 224 x (W) 214 x (T) 46 mm 

Housing Colours 

 

 

 

Front:

 RAL 9002 Gray-White, 

Back/Lid:

 RAL 7024 Graphite-Grey 

Enclosure Material 

 

 

 

Plastic (PC-ASA) 

Enclosure Rating 

 

 

 

IP67 

Weight 

 

 

 

iPOINT Si:  1200g

 

 

 

 

 

 

Order Code

 

 

 

 

 

iPOINT Si  (IDS1001) 

 

 

 

455970 

Pole Mount Bracket (kit) 

 

 

 

456001 

1

 The communication range depends on environmental conditions and national regulation limits 

2

 Other country frequencies are available, please contact IDENTEC SOLUTIONS 

 
 
 
 
 

Содержание iPOINT Si

Страница 1: ...IDENTEC SOLUTIONS Model IDS1001 iPOINT Si HARDWARE USER MANUAL...

Страница 2: ...y person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or reven...

Страница 3: ...nded This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Conformit l exposition aux champs RF des quipements radio Pour satisfaire aux exigences F...

Страница 4: ...crew on the unit Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit Avoid unnecessary contact with the unit connectors and assemblies inside t...

Страница 5: ...d cool environments Do not open the Main housing The Connection Chamber can be opened for required cabling needs but there is no need to open the main housing crews from bottom side in order to set th...

Страница 6: ...SB Connector Pinout 15 2 4 USB Only mode Function and specification 16 2 5 Communication Interface Priorities 16 2 6 Lid Open Detection 16 3 Initial Operation Configuration 17 3 1 Status LEDs 17 4 Mec...

Страница 7: ...the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided upo...

Страница 8: ...e Housing contains 5 Status LEDs see Section 3 1 a Connection Chamber where the wired interfaces can be accessed Relevant cable glands as wired access points depending on the device setup Mounting Pla...

Страница 9: ...cols The iPOINT X has two internal UHF antennas built in and can communicate up to a range of 500 meters with its Tags The main benefit of two antennas is the elimination of RF dead spots in static sy...

Страница 10: ...reserved 10 2 1 3 NFC Interface The NFC Interface is a Near Field Communication interface The iPOINT can be used as an entry terminal or for other NFC communication The range to the Tag is around 10 1...

Страница 11: ...racking and Tracing Localization Environmental Data Sensing i B350 Tags IDENTEC SOLUTIONS i B350 tags are designed to be cost effective and easy to implement while offering maximum flexibility The bea...

Страница 12: ...or for debugging low power operation and device configuration RS422 MASTER RJ45 RS422 cable connector to the host computer or previous Slave port in the daisychain RS422 SLAVE RJ45 RS422 cable connect...

Страница 13: ...d 13 RS422 with injected 24V Power installation Make sure power supply can handle all iPOINTs in the system USB Mode 5V Local USB mode over Mini USB Connector for debugging low power operation and Con...

Страница 14: ...units in the chain must not exceed 1000 m 3200 ft The distance from one unit to the next must not exceed 300 m 1000 ft This table is valid for Cat 5 cabling with gauge diameters of AWG24 0 25 mm of i...

Страница 15: ...r bus 8 GND GND Brown Power supply over bus As the TxD RxD crossing is done by the pinout of the connectors simple straight cabling has to be used Connection parameters Signal levels RS422 Baud rate 1...

Страница 16: ...ver TBD Enter config debugging info 2 5 Communication Interface Priorities The priorities for the wired connections will be 1 USB Highest priority A connection over USB will terminate all other existi...

Страница 17: ...Orange when a response or a broadcast is received LF This is the LF Communication LED LED blinks green when Marker Loop ID is sent It blinks red if LF is not working properly e g loop broken or loop...

Страница 18: ...from the front side until magnetic connection is released lift off 2 Loosen the 8x screws be aware DO NOT pull out the screws out completely the gasket can be damaged 3 Lift off the lid 4 Now you hav...

Страница 19: ...ting plate only 4x countersunk screws are required with a maximum diameter of 5mm or M5 screws Length and type shall be chosen depending on wall material 4x countersunk screws Choose screw type and le...

Страница 20: ...here s a risk of damage 4 2 1 Optional Extra Pole Mount Bracket Kit A Pole Mount Bracket Kit is available Pole Mount Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to...

Страница 21: ...xtension Bracket Kit is available Extension Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o Multiple mou...

Страница 22: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 22...

Страница 23: ...epends on the relevant system concept and very likely varies from one system to another A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors sec...

Страница 24: ...order to keep down times short it is recommended that these parameters are set before the component is entered into the spare part stock system In most cases all units within an identification system...

Страница 25: ...Interface USB USB Mini Status Display 5 LEDs UHF LF COM RUN NFC Electrical Power Source PoE 12 30VDC RS422 Master Power Consumption according to 802 3af3 Max 7 Watt Environmental Conditions Operating...

Страница 26: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 26...

Отзывы: