2.3.1 PoE Connector & Pinout
PoE interface: Shielded wire connection with PoE voltage, according to the Standard. RJ45 Plug.
View into the connector = crimp/solder side of plug
Pin
Symbol
T568B color
1
Rx+
White/orange
2
Rx-
Orange
3
Tx+
White/Green
4
Vdc+
Blue
5
Vdc+
White/Blue
6
Tx-
Green
7
Vdc-
White/Brown
8
Vdc-
Brown
2.3.2 RS422 Connectors & Pinout
There are limitations on the RS422 Master/Slave cabling:
Shielded cables must be used to achieve the prescribed EMC
The overall length of the RS422 Master/Slave over all units in the chain must not exceed 1000 m (3200 ft).
The distance from one unit to the next must not exceed 300 m (1000 ft).
This table is valid for Cat 5 cabling with gauge diameters of AWG24 (0.25 mm²).
# of i-PORTs
Length (m/ft)
Remark
1
300/1000
Central supply with 24 VDC via the RS422 Master/Slave
2
600/2000
Central supply with 24 VDC via the RS422 Master/Slave
3
400/1300
Central supply with 24 VDC via the RS422 Master/Slave
4
250/820
Central supply with 24 VDC via the RS422 Master/Slave
WARNING
The RS422 Master/Slave uses RS422 levels on its RX and TX Pins, although Ethernet jack/plugs mechanically
fit, the device is not Ethernet compatible.
If devices are powered by the RJ45 cabling of the RS422 Master/Slave, wire gauge must be at least AWG24
(0.25 mm²).
View into the connector = crimp/solder side of plug