background image

 

VISIBILITY DELIVERED. 

PAGE 3 OF 15 

 
IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: 
 

MODELS: 

i-B350 S, 

i-B350L 

S

 

 

Region/Country  Organization 

Marking 

EUROPE: 

EC  

CE 

USA 

FCC 

FFC ID 

OO

4-ILR-IB350LS 

Canada 

Industry Canada 

IC: 3538A-IB350LS 

 
 

European Notification according R&TTE Directive 

 
This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the 
following standards: ETSI EN 300 220, ETSI EN 301 489, EN 60950 
 

USA Notification 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation. 

The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by 
IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC 
SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance 
could void the users’ authority to operate the equipment. 
 
The device has been tested and found to comply with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may 
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely 
to cause harmful interference in which case the user will be required to correct the interference at his own 
expense. 
 

 

 
 

Содержание i-B350 S

Страница 1: ...ILR 350 Series i B350L S Installation and Operation Manual preliminary...

Страница 2: ...g from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such damages Trademarks IDENTEC...

Страница 3: ...ucts are cautioned to only use accessories and peripherals approved in advance by IDENTEC SOLUTIONS The use of accessories and peripherals other than those approved by IDENTEC SOLUTIONS or any changes...

Страница 4: ...PRECAUTIONS 3 TAG MOUNTING TECHNIQUES 5 3 1 DIMENSIONAL DRAWING 8 3 2 CABLE STRAPS 8 3 3 RIVETS 9 3 4 SCREWS 10 4 INITIAL OPERATION CONFIGURATION OF THE TAG 4 1 GENERAL 4 2 PING RATE 4 3 BURSTS WHEN P...

Страница 5: ...the tags and a system test can now be done 1 3 Scope of this Document This document is the users manual of the models i B350 S and i B350L S This document is intended only for mechanical installation...

Страница 6: ...8 F the tags are heated and must be handled with care To prevent burns wait until the tags have cooled down or use appropriate gloves At temperatures below 0 C 32 F tags can be frozen In this case wai...

Страница 7: ...d that only original products spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation service and repair Otherwise IDENTEC SOLUTIONS does not accept any responsibility for...

Страница 8: ...niques 1 1 Dimensional Drawing All dimensions in mm 1 2 Cable Straps The Tag can be mounted either with cable straps using the 2 slits at each end or using rivets or screws as described in the followi...

Страница 9: ...this might occur it is better to use a blind rivet with a large head Refer to UN9924 or insert a 5 32 washer This has the effect of distributing the pressure over a larger surface area during riveting...

Страница 10: ...need to be made of stainless steel or other non rusting material 4 A temperature of at least 10 C 50 F must be maintained during mounting to prevent the casing from cracking 5 Recommended maximum torq...

Страница 11: ...gular Pings Marker technology Bursts triggered by the push button can be configured independent from regular Pings Tools Needed PC running on MS Windows with the ILR Tag Configuration for ILR 350 seri...

Страница 12: ...rce to burst Possible settings are 40 100 200 300 400 500 600 and 700 ms Please read the details in the following subchapter Information on Burst Settings Marker Message Options Entering a marker fiel...

Страница 13: ...l all bursts are sent With very few tags the factory setting of 40 ms is sufficient In case there is the possibility that dozens of tags are triggered to burst at once this value can be increased This...

Страница 14: ...g products containing chemical additives 3 3 Precautionary Maintenance A regular check of the system is recommended Unstable connections could lead to damage and malfunctions of the system and should...

Страница 15: ...itions Communication Data Inductive Loop Marker Read range Up to several meters Operating frequency 125 kHz world wide approved Operation mode Receives marker ID number and transmits marker informatio...