    USER GUIDE 

and 

INSTALLATION GUIDE

 

NMEA Flash input  

interface 

Product reference : 90-60-360

 

Summary of Contents for NMEA 90-60-360

Page 1: ... competition Z I Kerandré Rue Gutenberg 56700 HENNEBONT FRANCE http www nke fr After sale service tel 33 0 892 680 656 REV 2 USER GUIDE and INSTALLATION GUIDE NMEA Flash input interface Product reference 90 60 360 ...

Page 2: ...FIED NMEA FRAMES 3 3 TECHNICAL SPECIFICATIONS 5 4 DIAGNOSTIC OF 1 ST LEVEL TROUBLESHOOTING 5 5 INSTALLATION 6 5 1 LIST OF ACCESSORIES 6 5 2 INSTALLATION PRECAUTIONS 6 5 3 HOUSING ASSEMBLY OF THE NMEA INPUT INTERFACE 6 5 4 CONNECTION TO THE TOPLINE BUS 7 5 5 INITIALISATION OF THE NMEA INPUT INTERFACE 8 ...

Page 3: ...e instrument of your installation IMPORTANT Please read this guide completely before starting the installation Any electrical connection on the TOPLINE bus must carried out with the terminal box 90 60 121 Only use TOPLINE bus cable 20 61 001 2 LIST OF IDENTIFIED NMEA FRAMES The NMEA input interface identifies the frames below The interface is thus able to create up to 40 NMEA channels on the Topli...

Page 4: ... C_WP_OD APA APB 21 B_PILOT APA APB XTE 22 YEARMONTH ZDA RMC 23 R_COMPAS HDG HDM VHW 24 R_ APP_WIND_ANG MWV VWR 25 LAT_DEGMIN GGA GLL RMC 26 LAT_MILMIN GGA GLL RMC 27 LON_DEGMIN GGA GLL RMC 28 LON_MILMIN GGA GLL RMC 29 V_WP WCV 30 TARGET_SPD KEP 31 OTHER_SIDE_HDG KEP 32 OPT_WIND_ANG KEP 33 PRES_EFF KEP 34 POLAR_EFF KEP 35 CMG_OPT_ANGLE KEP 36 VMG_OPT_ANGLE KEP 37 CMG_TRACK_GAIN KEP 38 VMG_TRACK_GA...

Page 5: ...do not require the intervention of a specialist Before contacting technical support please check the troubleshooting table below Problem Possible causes and solutions The Topline installation does not detect the NMEA Interface The NMEA frames do not show on the Topline display of your installation The bus cable is not or is badly connected to the terminal box check the plugging and the connection ...

Page 6: ...417 5 2 Installation precautions The housing of the NMEA input interface is waterproof against water spray Install the housing in a location that is unlikely to get flooded 5 3 Installation of the NMEA input interface housing Fix the housing in place using Ø4 screws CAUTION The connection of this sensor must be carried out with the power switched off unit mm Figure 1 ...

Page 7: ...cable strip and galvanise the wires before connecting them inside the terminal box Identification of the cable wires White cable 5 conductor wires Wire identification White wire 12V TOPLINE bus Black wire Topline data Braid Earth Red wire NMEA initialisation wire Yellow wire NMEA NMEA input Green wire NMEA BLANC GND NOIR BLANC GND NOIR 12V GND NMEA NMEA NMEA NMEA init Supply voltage 12Vdc Terminal...

Page 8: ...the red initialisation wire is disconnected then it creates the new channels that correspond to the NMEA frames transmitted by the instrument A sounding beep is emitted for each NMEA frame identified Reconnect the red initialisation wire to the init terminal or to the GND terminal Initialisation is then complete and you may select the NMEA channels on the Topline Multifunction displays of your ins...