manualshive.com logo in svg
background image

 

VISIBILITY DELIVERED. 

PAGE 15 OF 15 

4

 

Technical Data 

Operating Data 

Operating frequency ILR-RFID 

868 MHz (EU) or 920 MHz (NA), further frequencies on request 

Maximum transmission power 

< 1mW (EU / NA) 

Compatibility 

i-PORT M 350, i-CARD CF-350 

Standards/Certification 

FCC Part 15 (US), ETSI EN 300 220 (EU) 

Communication Data Long-Range RFID (ILR, Beacon Technology) 

Read range broadcast 

Up to 500 m (1600 feet) free air* 

Operation mode 

Transmits marker information in at regular intervals 

Repetition rate (ping rate) 

0,5 – 300 seconds, adjustable in steps of 0,5 seconds 

Data rate broadcast 

115.2 kbits/s 

* The communication range depends on the antenna type, the antenna cable runs and the 

environmental conditions. 

Communication Data Inductive Loop (Marker) 

Read range 

Up to several meters 

Operating frequency 

125 kHz (world-wide approved) 

Operation mode 

Receives marker ID number and transmits marker information several 
times 

Electrical 

Power source 

Lithium battery, non replaceable 

Battery monitoring 

Yes 

Data 

Data retention 

>10 years without power 

Write cycles 

100,000 writes to a tag  

Memory size 

10,000 Bytes user definable 

Identification code 

48 bit fixed ID 

Environmental Conditions 

Operating temperature 

–40 °C to +85 °C (–40 ºF to +185 ºF) 

Humidity 

10 % to 95 % relative humidity @ 30 °C 

Shock 

50 G, 3 times DIN IEC 68-2-27 
Multiple drops to concrete from 1 m (3 ft)  

Vibration 

3 G, 20 sine wave cycles, 5 Hz to 150 Hz, DIN IEC 68-2-6 
5 G, noise 5 Hz to 1000 Hz, 30 minutes, DIN IEC 68-2-64 

Physical  

Dimensions 

137 × 37.5 × 26.5 mm (5.4 × 1.48 × 1.04 in.) 

Enclosure 

Plastic 

Weight 

50 g (1.75 ounces) 

Enclosure rating 

IP 65 

 

Содержание i-B350 S

Страница 1: ...ILR 350 Series i B350L S Installation and Operation Manual preliminary...

Страница 2: ...g from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such damages Trademarks IDENTEC...

Страница 3: ...ucts are cautioned to only use accessories and peripherals approved in advance by IDENTEC SOLUTIONS The use of accessories and peripherals other than those approved by IDENTEC SOLUTIONS or any changes...

Страница 4: ...PRECAUTIONS 3 TAG MOUNTING TECHNIQUES 5 3 1 DIMENSIONAL DRAWING 8 3 2 CABLE STRAPS 8 3 3 RIVETS 9 3 4 SCREWS 10 4 INITIAL OPERATION CONFIGURATION OF THE TAG 4 1 GENERAL 4 2 PING RATE 4 3 BURSTS WHEN P...

Страница 5: ...the tags and a system test can now be done 1 3 Scope of this Document This document is the users manual of the models i B350 S and i B350L S This document is intended only for mechanical installation...

Страница 6: ...8 F the tags are heated and must be handled with care To prevent burns wait until the tags have cooled down or use appropriate gloves At temperatures below 0 C 32 F tags can be frozen In this case wai...

Страница 7: ...d that only original products spare and replacement parts authorized by IDENTEC SOLUTIONS be used for installation service and repair Otherwise IDENTEC SOLUTIONS does not accept any responsibility for...

Страница 8: ...niques 1 1 Dimensional Drawing All dimensions in mm 1 2 Cable Straps The Tag can be mounted either with cable straps using the 2 slits at each end or using rivets or screws as described in the followi...

Страница 9: ...this might occur it is better to use a blind rivet with a large head Refer to UN9924 or insert a 5 32 washer This has the effect of distributing the pressure over a larger surface area during riveting...

Страница 10: ...need to be made of stainless steel or other non rusting material 4 A temperature of at least 10 C 50 F must be maintained during mounting to prevent the casing from cracking 5 Recommended maximum torq...

Страница 11: ...gular Pings Marker technology Bursts triggered by the push button can be configured independent from regular Pings Tools Needed PC running on MS Windows with the ILR Tag Configuration for ILR 350 seri...

Страница 12: ...rce to burst Possible settings are 40 100 200 300 400 500 600 and 700 ms Please read the details in the following subchapter Information on Burst Settings Marker Message Options Entering a marker fiel...

Страница 13: ...l all bursts are sent With very few tags the factory setting of 40 ms is sufficient In case there is the possibility that dozens of tags are triggered to burst at once this value can be increased This...

Страница 14: ...g products containing chemical additives 3 3 Precautionary Maintenance A regular check of the system is recommended Unstable connections could lead to damage and malfunctions of the system and should...

Страница 15: ...itions Communication Data Inductive Loop Marker Read range Up to several meters Operating frequency 125 kHz world wide approved Operation mode Receives marker ID number and transmits marker informatio...

Отзывы: