2: P
RODUCT
S
PECIFICATIONS
2-12
FC6A S
ERIES
MICROS
MART
U
SER
’
S
M
ANUAL
FC9Y-B1722
Function Specifications
■
CPU Module Performance
*1 1 step is equivalent to 8 bytes.
*2 As given below, certain digital I/O cartridges cannot be used in cartridge slot 3 depending on the configuration of expansion modules.
Limitations on Using Digital I/O Cartridges
*3 A maximum of two or three cartridges can be used by connecting the HMI module.
*4 There are limitations on the maximum number of outputs that can be simultaneously turned on.
For details, see "Connection Restrictions When Expanding the PLC" on page 3-34.
*5 The maximum number of expansion modules that can be connected can be increased by using the expansion interface module. For details, see
"Expansion Interface Modules" on page 2-110.
Backup Function
Clock Function
Type No.
FC6A-C16R1AE
FC6A-C16R1CE
FC6A-C16K1CE
FC6A-C16P1CE
FC6A-C24R1AE
FC6A-C24R1CE
FC6A-C24K1CE
FC6A-C24P1CE
FC6A-C40R1AE
FC6A-C40R1CE
FC6A-C40K1CE
FC6A-C40P1CE
FC6A-C40R1DE
FC6A-C40K1DE
FC6A-C40P1DE
FC6A-C40R1AEJ
FC6A-C40R1CEJ
FC6A-C40K1CEJ
FC6A-C40P1CEJ
FC6A-C40R1DEJ
FC6A-C40K1DEJ
FC6A-C40P1DEJ
Program
Capacity
Program Data
72,000 bytes
(9,000 steps)
* Writable during run-time
384,000 bytes
(48,000 steps)
* Not writable during run-time
640,000 bytes
(80,000 steps)
* Not writable during
run-time
Comment Data
256,000 bytes
256,000 bytes
I/O Expansion
Basic Expansion
4
7
7
7
Expansion Interface
8
8
8
8
2
2
3
3
I/O Points
Basic
Input
9
14
24
24
Output
7
10
16
16
Basic Expansion
128
224
224
224
Expansion Interface
256
256
256
256
8
8
12
12
User Program Download
1,000 times
Control System
Stored program system
Instructions
Basic Instructions
42 types
Advanced Instructions
124 types
Processing Speed
Basic Instruction
0.042 ms/1,000 steps
END Processing
1 ms
Internal Relay
12,400
Shift Register
256
Data Register
54,000
Counter (adding, reversible)
512
Timer (1 ms, 10 ms, 100 ms, 1 s)
1,024
Configuration of Expansion Modules
Digital I/O Cartridges That Cannot Be Used in Cartridge Slot 3
FC6A-N32B3×15
FC6A-PN4
FC6A-T32K3 and FC6A-T32P3×15
FC6A-PTK4, FC6A-PTS4
Backup Data
RAM (internal relays, shift registers, counters, data registers), clock
Backup Battery
Lithium ion primary cell (replaceable, BR2032)
Backup Duration
Guaranteed 1 year, replacement recommended every 4 years at 25°C
Replaceability
Yes (within 1 minute after power off)
Accuracy
±30 seconds/month at 25°C
Содержание MICROSmart FC6A Series
Страница 1: ...B 1722 8 FC6A SERIES User s Manual...
Страница 12: ...TABLE OF CONTENTS Preface 11 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 182: ...2 PRODUCT SPECIFICATIONS 2 152 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 434: ...8 INSTRUCTIONS REFERENCE 8 18 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 520: ...11 SD MEMORY CARD 11 54 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 554: ...13 TROUBLESHOOTING 13 26 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 567: ...FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722 A 13 APPENDIX ASCII Character Code Table...