FC6A S
ERIES
MICROS
MART
U
SER
’
S
M
ANUAL
FC9Y-B1722
1-13
1: G
ENERAL
I
NFORMATION
Allocations of the Communication Port Numbers
All-in-One CPU module, CAN J1939 All-in-One CPU module, and Plus CPU module support serial communication with the target
device. Serial communication is possible with built-in interface or expanded interface of each CPU module. Interfaces supporting
the serial communication are as follows:
In order to use each interface as communication port, the communication parameters must be configured according to the
communication parameters of the target device. Configure the communication parameters in
Communiction Ports
tab in the
Function Area Settings
dialog box. The allocation between each interface and communication port is described below.
For details on each setting, refer to chapter 3 "Communication Port Settings" in the "FC6A Series MICROSmart Communication
Manual".
■
Ports and Cartridge Slots 1 to 3 on the CPU Module and HMI Module
*1 When the HMI module is connected to the CPU module and HMI-Ethernet port is added.
*2 When a communication cartridge is installed on the cartridge slot.
*3 When the cartridge base module is connected to the CPU module and a communication cartridge is installed on the cartridge slot.
*4 When the HMI module is connected to the CPU module and a communication cartridge is installed on the cartridge slot.
*5 The combination of "Data Bits: 7" and "Parity: None" is not possible.
Notes:
For the locations of each port and cartridge slot, see "Part Names and Functions" on page 2-2.
For serial port 1 wiring, see "Other Inputs and Ports" on page 2-35. For communication cartridge wiring, see "Terminal Arrangement and
Wiring Examples" on page 2-142.
■
Ports on Communication Modules
*1 Four or more communication modules cannot be connected to the All-in-One CPU module and CAN J1939 All-in-One CPU module.
All-in-One CPU module
: Serial port 1, cartridge slots 1 and 2, communication module ports
CAN J1939 All-in-One CPU module
: Cartridge slots 1 and 2, communication module ports
Plus CPU module
: Cartridge slots 1 to 3, communication module ports
— : Not equipped with the CPU module.
No : Cannot be used as the serial communication ports.
CPU Module
Port
Cartridge Slot
Serial
Port 1
USB
Port
Ethernet
Port 1
Ethernet
Port 2
HMI-
Ehternet
Port
CAN
Port
1
2
3
All-in-One CPU module
16-I/O type
Port 1
No
No
—
—
Port 2
—
—
24-I/O type
40-I/O type
Port 3
CAN J1939 All-in-One
CPU module
40-I/O type
—
No
Plus CPU module
Plus 16-I/O type
No
—
Port 1
Port 2
Port 3
Plus 32-I/O type
CPU Module
Communication Module
1st
2nd
3rd
4th
···
15th
All-in-One CPU module
16-I/O type
Port 4, 5
Port 6, 7
Port 8, 9
24-I/O type
40-I/O type
CAN J1939 All-in-One
CPU module
40-I/O type
Plus CPU module
Plus 16-I/O type
Port 10, 11
···
Port 32, 33
Plus 32-I/O type
Содержание MICROSmart FC6A Series
Страница 1: ...B 1722 8 FC6A SERIES User s Manual...
Страница 12: ...TABLE OF CONTENTS Preface 11 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 182: ...2 PRODUCT SPECIFICATIONS 2 152 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 434: ...8 INSTRUCTIONS REFERENCE 8 18 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 520: ...11 SD MEMORY CARD 11 54 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 554: ...13 TROUBLESHOOTING 13 26 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Страница 567: ...FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722 A 13 APPENDIX ASCII Character Code Table...