The FC6A Series MicroSmart has an automatic BCC calculation function to detect a communication error in incoming data. If a BCC
code is designated in the receive format of a RXD instruction, the FC6A Series MicroSmart calculates a BCC value for a specified
starting position through the position immediately preceding the BBC. It then compares the calculation result with the BCC code in
the received incoming data. The start position for the BCC calculation can be specified from the first byte through the 15th byte.
The BCC can be 1 or 2 digits.
When an end delimiter is not used in the RXD instruction, the BCC code must be positioned at the end of the receive format
designated in Source 1 device. When an end delimiter is used, the BCC code must be immediately before or after the end delimiter.
The FC6A Series MicroSmart reads a specified number of BCC digits in the incoming data according to the receive format to
calculate and compare the received BCC code with the BCC calculation results.
BCC Calculation Start Position
The start position for the BCC calculation can be specified from the first byte through the 15th byte. The BCC is calculated for the
range starting at the designated position up to the byte immediately before the BCC of the receive data.
Example: Received data consists of 17 bytes plus 2 BCC digits.
(1) Calculation start position = 1
(2) Calculation start position = 2
BCC Calculation Formula
BCC calculation formula can be selected from XOR (exclusive OR), ADD (addition), ADD-2comp, Modbus ASCII, or Modbus RTU.
Example: Incoming data consists of 41h, 42h, 43h, and 44h.
(1) BCC calculation formula = XOR
Calculation result = 41h
⊕
42h
⊕
43h
⊕
44h = 04h
(2) BCC calculation formula = ADD
Calculation result = 41h
+
42h
+
43h
+
44h = 10Ah
→
0Ah (Only the last 1 or 2 digits are used as BCC.)
(3) BCC calculation formula = ADD-2comp
Calculation result = FEh, F6h (2 digits without conversion)
(4) BCC calculation formula = Modbus ASCII
Calculation result = 88 (ASCII)
(5) BCC calculation formula = Modbus RTU
Calculation result = 85h 0Fh (binary)
STX
BCC calculation range
1st
“A”
2nd
“B”
3rd
“C”
4th
“D”
5th
“E”
6th
“0”
15th
CR
16th
LF
17th
BCC
18th
BCC
19th
BCC
(2 digits)
STX
BCC calculation range
1st
“A”
2nd
“B”
3rd
“C”
4th
“D”
5th
“E”
6th
“0”
15th
CR
16th
LF
17th
BCC
18th
BCC
19th
BCC
(2 digits)
Содержание MICROSmart FC6A-C16K1CE
Страница 1: ...B 1730 2 FC6A SERIES All in One Type Communication Manual...
Страница 60: ...3 COMMUNICATION SETTINGS 3 22 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730...
Страница 76: ...4 MAINTENANCE COMMUNICATION 4 16 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730...
Страница 126: ...5 USER COMMUNICATION INSTRUCTIONS 5 50 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730...
Страница 158: ...6 MODBUS COMMUNICATION 6 32 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730...
Страница 200: ...8 J1939 COMMUNICATION 8 32 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730...
Страница 218: ...10 SEND E MAIL FUNCTION 10 16 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730...
Страница 252: ...INDEX 4 FC6A SERIES MICROSMART ALL IN ONE TYPE COMMUNICATION MANUAL FC9Y B1730 INDEX...