MICRO/I Hardware Manual
1-23
2 HG5G/4G/3G/2G-V
1
M
ain
U
nit S
pe
cific
atio
ns
■
Performance Specifications
Type Number
HG5G-V
HG4G-V
HG3G-VA
HG3G-V8
HG2G-V
Display
LCD Type
TFT color LCD
(TN Type)
TFT color LCD (IPS Type)
TFT color LCD
(TN Type)
Display Colors
65,536 Colors
Effective Display Area 304.1 (W) ×
228.1 (H) mm
245.76 (W) ×
184.32 (H)
mm
210.4 (W) ×
157.8 (H)
mm
170.496 (W) ×
127.872 (H)
mm
115.2 (W) ×
86.4 (H) mm
Display Resolution
1024 (W) × 768 (H) dots
640 (W) ×
480 (H) dots
View angle
Left/Right/Bottom: 80°,
Top: 60°
Left/Right/Top/Bottom: 85°
Left/Right/Top/
Bottom: 80°
Brightness of LCD only 650 cd/m
2
600 cd/m
2
700 cd/m
2
800 cd/m
2
800 cd/m
2
Brightness Adjustment 48 levels
Backlight
LED (white)
Backlight Life
Approx. 100,000 hours (The time until brightness becomes 50% of the initial value)
Touch
Panel
Switch Type
Analog Resistive Film
Operating Force
3N maximum
Multiple Operations
Impossible
Life
1,000,000 operations
User Memory
Approx. 58 MB
Backup Battery
Coin type lithium manganese dioxide battery CR2032W
Guarantee Period: 1 Year (Ambient Operating Temperature at 25°C)
Recommended Replacement Span: Every 5 Years (Ambient Operating Temperature at
25°C)
Backup Data
Calendar, Log Data, HMI Keep Relays, HMI Keep Registers
Buzzer output
Single tone (tone length is adjustable)
Degree of Protection
IP66F, IP67F (IEC 60529)
TYPE 4X (indoor use only)
TYPE 13
Weight (approx.)
3.2kg
2.1kg
1.65 kg
1.25 kg
0.65 kg
*1 Please be aware that small black and bright dots might show up on LCD Screen: it is not a failure or malfunction.
*2 The life of the LCD itself at an ambient temperature of 25°C. This is not a guaranteed value. The actual life depends on the
environment and conditions of use.
*3 It is a protection structure for the operating surface of HMI, which is attached to a panel. Although protection structure
suffices every test conditions, it does not guarantee to operate under all of the environmental condition. As for IP66F/IP67F
oilproof structure, it suffices oilproof test conditions. Conditions are listed in the document that comes with Japanese
Industrial Standard JIS C 0920. Protection structure do not guarantee usage under long exposure to oil or usage of oil that
is not prescribed in the document. Please test/check beforehand to avoid trouble.