Diagnostics
HR9Z-B2200 8/2020
87
Diagnostics via Status Output Z1
Overview
The pulsed output Z1 provides diagnostics information in the form of a bit pattern.
Refer to the chapter Electrical Installation
) for additional information on wiring the Z1.
Diagnostics Codes
The device encodes diagnostics information into sequences of 10 bits with a total of 2 s (each bit
200 ms).
The first four bits (0010) represent the beginning of a bit sequence. The next six bits contain the
diagnostics code itself.
The following table lists the bit sequences of the diagnostics codes, the description of the
corresponding status as well as correctives, if applicable.
WARNING
INCORRECT USE OF OUTPUT
Do not use the additional output Z1 for safety-related purposes.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Bit sequence
Description
Correctives
Type
(1)
0010101101
Supply voltage out of
tolerance.
Verify correct wiring.
Use a suitable power supply.
E
0010000011
General error detected.
Verify correct wiring.
Perform a power cycle.
If the error persists, replace the device.
E
0010000110
General error detected in
expansion module.
Verify correct wiring.
Perform a power cycle of the base safety module and the
connected extension module.
If the error persists, replace the extension module.
E
0010000111
Configuration error
detected. The position of
at least one of the
selectors has been
modified during
operation.
Verify that the position of the selectors is appropriate for
the application to be implemented.
Perform a power cycle.
If the error persists, replace the device.
E
(1) Type of message: E = Error detected, A = Alert, S = Status information
Содержание HR6S-DN
Страница 1: ...http www idec com HR6S DN Safety Module Original instructions HR9Z B2200...
Страница 8: ...8 HR9Z B2200 8 2020...
Страница 14: ...14 HR9Z B2200 8 2020...
Страница 20: ...Introduction 20 HR9Z B2200 8 2020...
Страница 56: ...Installation 56 HR9Z B2200 8 2020...
Страница 60: ...Functions 60 HR9Z B2200 8 2020 Wiring of the inputs for Emergency Stop Wiring of the inputs for guards...
Страница 64: ...Functions 64 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Страница 66: ...Functions 66 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Страница 69: ...Functions HR9Z B2200 8 2020 69 Wiring of the inputs for sensors devices with two PNP outputs...
Страница 72: ...Functions 72 HR9Z B2200 8 2020 Wiring of the inputs for sensors devices with OSSD outputs...
Страница 98: ...Accessories Service Maintenance and Disposal 98 HR9Z B2200 8 2020...