Synchronization:
Characteristic
Value/Description
Typical applications
Monitoring of electro-sensitive protective
equipment such as type 4 light curtains as per
IEC 61496-1
Monitoring of RFID sensors
Type of outputs of sensor/device providing the input signal
for application function
OSSD (Output Signal Switching Device) outputs
S## terminals to be connected
S12 and S13 for sensor/device A
S22 and S23 for sensor/device B
S32 and S33 for sensor/device C
S42 and S43 for sensor/device D
S52 and S53 for sensor/device E
S62 and S63 for sensor/device F
If less than 6 safety-related inputs are used, the terminals
S#1, S#2 and S#3 of the unused safety-related inputs
must be bridged (example: sensor/device F not
connected: S61, S62 and S63 bridged).
Do not configure a start function with startup test if less
than 6 safety-related inputs are used.
Dynamization
No
Signal interlock monitoring
Between terminals S12 and S13
Between terminals S22 and S23
Between terminals S32 and S33
Between terminals S42 and S43
Between terminals S52 and S53
Between terminals S62 and S63
Synchronized terminals
Synchronization time
S12 synchronized with S13
S12 and S13 have to be activated within 0.5 s.
S22 synchronized with S23
S22 and S23 have to be activated within 0.5 s.
S32 synchronized with S33
S32 and S33 have to be activated within 0.5 s.
S42 synchronized with S43
S42 and S43 have to be activated within 0.5 s.
S52 synchronized with S53
S52 and S53 have to be activated within 0.5 s.
S62 synchronized with S63
S62 and S63 have to be activated within 0.5 s.
Содержание HR6S-DN
Страница 1: ...http www idec com HR6S DN Safety Module Original instructions HR9Z B2200...
Страница 8: ...8 HR9Z B2200 8 2020...
Страница 14: ...14 HR9Z B2200 8 2020...
Страница 20: ...Introduction 20 HR9Z B2200 8 2020...
Страница 56: ...Installation 56 HR9Z B2200 8 2020...
Страница 60: ...Functions 60 HR9Z B2200 8 2020 Wiring of the inputs for Emergency Stop Wiring of the inputs for guards...
Страница 64: ...Functions 64 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Страница 66: ...Functions 66 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Страница 69: ...Functions HR9Z B2200 8 2020 69 Wiring of the inputs for sensors devices with two PNP outputs...
Страница 72: ...Functions 72 HR9Z B2200 8 2020 Wiring of the inputs for sensors devices with OSSD outputs...
Страница 98: ...Accessories Service Maintenance and Disposal 98 HR9Z B2200 8 2020...