OPERATION:

High Voltage Warning (HI-V) 

The meter beeps and lights an LED when measuring > 30V AC on the VAC function and >30V 

DC when on the VDC function. 

Notes: This features does not work in the Ohm, capacitor, continuity or clamp modes. Audible 

indication can be disabled by pressing and holding the Max/min button while turning the 

function switch from OFF to any desired Function. Wait for 

Hb

 to be displayed and then release 

the button. To enable, turn the unit off and back on.

Data Hold Feature

Press the Hold button on the side of the meter to toggle in and out of the data hold mode.  

“HOLD” appears in the upper left of the meter display when data hold is active.  Use the data 

hold feature to lock a measurement reading on the display. Press the Hold button again to 

unlock the display and obtain a real-time reading.

Peak Feature

In PEAK mode, the meter display the PEAK value of AC Volts or Current measurement.

PEAK function is enabled by Depressing the PEAK HOLD button for > 2 seconds. 

To Exit PEAK Mode Depress the PEAK HOLD button again for > 2 seconds. 

Max/Min Feature 

The Max/Min records the maximum  and minimum measured value. Press the Max/Min button 

to activate this feature and to toggle between max, and Min readings. The unit will continually 

capture max and min values over time. Depressing the max/min button for >2 sec. exits the 

mode. Note: To record max/min values over a time period >30 min, the Auto Power Off (APO) 

feature must be defeated.

Relative Mode

Press “

” button to enter the Relative mode. The “

” symbol is displayed, and the value on

the display is subtracted and stored as a reference value. In the Relative mode, the value shown

on the display is always the difference between the stored reference value and the present

reading. Press the “

” button again for > 2 seconds to exit the Relative mode.

Zero Feature (61-775 model only)

The “ZERO” button is used to zero out the display before measuring DC current. Press the

“ZERO” button to subtract out the non-zero number. Then, measure the DC amps. Pressing the

“ZERO” button again causes the “ZERO” to flash and the original offset number to be displayed.

Depress the “ZERO” button for >2 sec. to exit this mode.

5

Note:  61-775 model also measures DC Current.

INCORRECT

Currents

cancel

CORRECT

Single 

Conductor

only

H

N

Auto Power Off (APO) Feature

The meter automatically powers itself down after about 30 minutes of no use. Press any

button, and the meter will wake up and display the last reading taken before power down. 

To Disable APO, press and hold the (      / Hz) button while turning the dial to any desired 

function. When APO is defeated, the “APO” will be removed from the display. Turning the meter 

off and back on will restore the APO default.

Backlight

Press the      button in the middle of the meter to turn the back-

light on and off. The green backlight will remain lit for about 

3 minutes before it automatically turns off to conserve

battery power. 

Note:  Backlight consumes 4x the battery power. 

Measuring AC Current (Amps):

INR

USH

Backlight on in

all functions.

Содержание TightSight 61-773

Страница 1: ...t Replace battery as soon as battery indicator appears to avoid false readings Remove the test leads from the meter prior to removing battery cover Do not use without the battery and battery cover pro...

Страница 2: ...n making accurate measurements on complex wave shapes like those found on Adjustable Speed Drives ASDs 1 10 11 3 15 4 5 9 12 13 14 6 8 7 2 APO HOLD MAX MIN P P mVA nm F kM Hz AC DC 4 Main Display Icon...

Страница 3: ...min the Auto Power Off APO feature must be defeated Relative Mode Press button to enter the Relative mode The symbol is displayed and the value on the display is subtracted and stored as a reference v...

Страница 4: ...oltage 7 DC Voltage AC Voltage Verifying Continuity Verify the circuit is de energized The meter will sense the level of resistance and beep if the resistance is less than 30 to confirm that continuit...

Страница 5: ...Indication The appears in the display with insufficient voltage for about one hour Then bAtt then displays for 5 seconds and unit powers down Indicator duration varies by battery brand Power Supply 1...

Страница 6: ...able product to relevant facilities in accordance with statutory regulations The crossed out wheeled bin indicates the product needs to be disposed separately and not as municipal waste Disposal of u...

Страница 7: ...ue voltajes superiores a las nominales al mult metro Quite las sondas de los puertos de entrada antes de medir corriente Reemplace la bater a tan pronto aparezca el indicador de carga de bater a baja...

Страница 8: ...ero y medida de corriente continua CC Ambos modelos emplean un circuito de rechazo de alta frecuencia HFR para filtrar el ruido o contribuir a realizar medidas exactas de ondas de formas complejas com...

Страница 9: ...ar los valores m ximos o m nimos medidos en un per odo de tiempo mayor que 30 minutos debe anularse la caracter stica de apagado autom tico APO Modo relativo Pulse el bot n para entrar al modo relativ...

Страница 10: ...CA 20 Verificaci n de continuidad Verifique que el circuito est desenergizado El instrumento detecta el nivel de resistencia y emite un pitido si la resistencia es menor que 30 para confirmar que exis...

Страница 11: ...calina 61 773 y 61 775 Indicaci n de bater a El s mbolo aparece en la pantalla durante alrededor de una descargada hora cuando el voltaje de la bater a es insuficiente Luego aparece bAtt por 5 segundo...

Страница 12: ...olver el producto fuera de servicio a los establecimientos correspondientes El s mbolo del cubo de residuos con ruedas tachado con una cruz indica que la disposici n final del producto debe realizarse...

Страница 13: ...nsion nominale Retirer les conducteurs d essai des conducteurs d essai ses prises avant de mesurer le courant Remplacer la pile d s que le t moin de pile est affich afin d viter les fausses lectures R...

Страница 14: ...ection par valeurs efficaces r elles et mesure le courant continu Les deux mod les utilisent un circuit de rejet de haute fr quence qui filtre le bruit et permet de r aliser des mesures pr cises sur d...

Страница 15: ...gristrer les valeurs maxi mini sur une p riode de plus de 30 mn il faut invalider la fonction d arr t automatique APO Mode relatif Appuyer sur le bouton pour passer sur le mode Relatif Le symbole est...

Страница 16: ...Tension c a 32 V rification de la continuit V rifier que le circuit est d sexcit Le multim tre d tectera le niveau de r sistance et mettra un signal sonore si la r sistance est inf rieure 30 pour con...

Страница 17: ...de la 100 heures d utilisation en continu avec une pile alcaline pile 61 773 61 775 T moin de d charge Le symbole s affiche pendant une heure environ en pr sence de piles d une tension insuffisante b...

Страница 18: ...tallations pertinentes conform ment aux r glements Les poubelles roues barr es indiquent que le produit doit tre vacu s par ment et non avec les ordures municipales Evacuation des piles accumulateurs...

Отзывы: