Response SE Combi -
Installation
INSTALLATION
36 FITTING THE KIT
Appliances fitted with a
REAR
outlet flue
; please refer to Frame 11
Appliances fitted with a
SIDE
outlet flue
; please refer to Frame 21
1.
Remove the cardboard support aid from the flue
and place safely to one side.
2.
Fit inner flue seal.
3.
Fit the inner flue extension duct onto the inner flue
duct.
4.
Fit the outer flue extension duct onto the outer air
duct.
5.
Drill one 3.2mm (1/8") dia hole through the outer
air duct.
Do not drill the inner flue duct.
6.
Insert the self tapping screw provided to fix the air
duct in position.
7.
Repeat steps 1-5 if a second flue extension is
required.
8.
Measure and mark the flue length required onto
the flue, measuring from the groove near the
terminal.
9.
To ensure a square cut, mark the flue all the way
round.
10.
Cut to length using the cardboard support aid.
11.
Remove the cardboard offcuts and deburr the
metal edges.
TOP
GROOVE
6
11
3
2
4
5
Res 1488