29 ASSEMBLING THE FLUE
30 CONNECTING THE FLUE TO THE BOILER
1
2
3
4
TOP
GROOVE
Res1484
1.
Fit the 'cut to length' flue on to the flue
turret.
Note.
Ensure the groove in the flue
aligns with the top of the turret
.
2.
Drill a 3.2mm dia. hole through the flue
via the hole present in the turret.
3.
Before securing the turret to the flue
terminal, fit the inner flue seal to the
turret.
4.
Secure the turret to the flue, using the
self tapping screw provided.
Note.
BEFORE fitting the flue turret, fill the condensate trap within
the boiler by pouring a cupful of water into the flue outlet A.
Res1486
4
Inner flue seal
3
A
2
1.
Insert the flue assembly through the
prepared hole in the wall far enough to
allow the rubber seal to unfold
completely and form an adequate seal
on the outside wall.
2.
Pull the flue back and locate the flue
turret on the top of the boiler ensuring
that the seal is in place.
3.
Secure the flue turret on top of the boiler
by inserting the open ends of the turret
clamp under the 2 studs and fixing it in
the middle with the single M5 x 10mm
pozi-hex screw provided.
4.
After securing the flue turret to the top of
the boiler slide the inner flue seal along
the terminal to make contact with the
wall.
Note.
There is no need to make good
the inside wall face around the flue.
5.
Flues over 1 metre long.
Fix the flue support bracket to the wall,
using the wall plug and wood screw.
For standard installations use the short
wood screw.
If the stand-off option is used, secure
the support bracket using the spacer
bracket and long wood screw.
SIDE FLUE OUTLET