31
Installation and Servicing
SECTION 2 - INSTALLATION
IMPORTANT
- when filling:
When filling there may be a slight water leak from the air vent therefore electrical connections should be protected.
Filling
1.
Ensure filling loop is connected and all washers in place.
2. Ensure dust cap on auto air vent is slackened off.
3. Check the following isolation handles on water connections
are in the horizontal filling position (blue handle on DHW
inlet
A
and black handle on CH return
C
).
Note
. The CH flow isolation valve handle MUST be in the
vertical position to enable filling.
4.
Slowly turn the filling loop handle (blue
B
) to the
horizontal open position until the pressure gauge reads
between 1 to 1.5 bar.
5. Once the pressure gauge dial reads between 1 to1.5 bar
turn the filling loop handle (blue
B
) back to the closed
(vertical) position.
6. Turn the CH Return handle (black
C
) and the DHW Inlet
handle (blue
A
) to the open (vertical) position.
7.
Disconnect the filling loop from the DHW Inlet valve and fit
the grey cap to the open end.
8.
Fit the Plug to the free end of the filling loop.
Note. Open all DHW taps to ensure water is flowing freely.
Once satisfied close all taps.
Top Up
1.
Ensure filling loop is connected and all washers in place.
2. Ensure dust cap on auto air vent is slackened off.
3. Turn the DHW Inlet handle (blue
A
) to the horizontal
position.
4.
Slowly turn the filling loop handle (blue
B
) to the
horizontal open position until the pressure gauge reads
between 1 to 1.5 bar.
5. Once the pressure gauge dial reads between 1-1.5 bar
turn the handle (blue
B
) on the filling loop back to the
closed (vertical) position.
6. Turn the DHW Inlet handle (blue
A
) to the open (vertical)
position.
7.
Disconnect the filling loop from the DHW Inlet valve and fit
the grey cap to the open end.
8.
Fit the Plug to the free end of the filling loop.
Note. Open all DHW taps to ensure water is flowing freely.
Once satisfied close all taps.
FILLING
A
A
B
C
B
C
CONNECTIONS & FILLING - CONT........
INST
ALLA
TION
Filling Loop
(Blue)
Filling Loop
(Blue)
CH Return
(Black)
CH Return
(Black)
DHW Inlet
(Blue)
DHW Inlet
(Blue)
Cap
Cap
Plug
Plug
Filling
Loop
Filling
Loop
Filling Positions shown
Top Up Positions shown
Содержание VOGUE COMBI C32IE
Страница 4: ...4 Installation and Servicing...
Страница 6: ...6 Installation and Servicing...
Страница 74: ......