22
Installation and Servicing
FLUE OUTLET
SECTION 2 - INSTALLATION
100mm
Edge of turret
to outside face of wall plus
44mm = flue length
Centre of turret to edge of turret = 100mm
Turret has a flue insertion of 30mm
The distance from the outer wall face to the wall seal flue mounting point is 14mm
Wall Mounted template & Flue
NOTES
REAR
Fit
to wall
A
W
ALL
Edge of turret
to outside face of wall plus
44mm = flue length
Flue length measured from outer terminal lip
to end of outer flue
A + 44mm
REAR
Fit
to wall
inc. Stand
off Frame
A
W
ALL
Edge of turret
to outside face of wall plus
44mm = flue length
SIDE
Fit
to wall
A
W
ALL
Minimum clearance 2.5mm
DETERMINING THE FLUE LENGTH AND FLUE PACKS REQUIRED, CONT’D
Actual maximum flue length requirements
(outside edge of turret to out side face of wall plus 44mm (Cut Length))
Minimum & Maximum finished flue lengths obtainable (dimension ‘A’ +44mm)
Horizontal Flue Terminal
(600mm long) B Pack
Telescopic Flue B Pack
Horizontal Flue
Terminal (1000mm long)
B Pack (Telescopic)
Horizontal Flue Terminal
(1000mm long) B Pack
(Telescopic) Cut 75mm
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
B Pack (Standard)
233
602
340
553
652
869
577
794
Plus 1 (1m D pack)
1183
1552
1290
1503
1602
1819
1527
1744
Plus 2 (1m D pack)
2133
2502
2240
2453
2552
2769
2477
2694
Plus 3 (1m D pack)
3083
3452
3190
3403
3502
3719
3427
3644
Plus 4 (1m D pack)
4033
4402
4140
4353
4452
4669
4377
4594
Plus 5 (1m D pack)
4983
5352
5090
5303
5402
5619
5327
5544
Plus 6 (1m D pack)
5933
6302
6040
6253
6352
6569
6277
6494
Plus 7 (1m D pack)
6883
7252
6990
7203
7302
7519
7227
7444
Plus 8 (1m D pack)
7833
8202
7940
8153
8252
8469
8177
8394
Plus 9 (1m D pack)
8783
9152
8890
9103
9202
9419
9127
9344
Plus 10 (1m D pack)
9733
N/A
9840
10000
N/A
N/A
N/A
N/A
Max output 32 & 40 kW
Max output 26 kW
FIGURE 1
FIGURE 2
Note. Maximum permissible
flue length is measured from
centre line of appliance flue
outlet to outside wall face.
Note; Telescopic flue B Pack or attached “D” pack extensions do not need to be cut between minimum and maximum values
shown above (except where specified). Horizontal Flue Terminal (600mm long) B Pack flue will require cutting on values
below maximum values shown above.
Содержание VOGUE COMBI C32IE
Страница 4: ...4 Installation and Servicing...
Страница 6: ...6 Installation and Servicing...
Страница 74: ......