2
Installation and Servicing
MODEL
SYMBOL
UNITS
C26
C32
C40
Condensing Boiler
n/a
n/a
yes
yes
yes
Low Temperature Boiler
n/a
n/a
no
no
no
B1 Boiler
n/a
n/a
no
no
no
Cogeneration Space Heater
n/a
n/a
no
no
no
Equipped with a Supplementary Heater
n/a
n/a
no
no
no
Combination Heater
n/a
n/a
yes
yes
yes
Nominal Heat Output for Space Heating
Full Load
P
4
kW
18
26
32
Part Load
P
1
kW
5.9
8.5
10.4
Auxiliary Electricity Consumption
Full Load
el
max
kW
0.047
0.063
0.044
Part Load
el
min
kW
0.014
0.011
0.01
Standby
P
SB
kW
0.003
0.003
0.003
Seasonal Space Heating Energy Efficiency
Full Load
ƞ
4
%
89.7
89.9
89.7
Part Load
ƞ
1
%
97.7
97.8
97.5
Standby Loss
P
stby
kW
0.02
0.02
0.02
Ignition
P
ign
kW
0
0
0
Emissions Nox (Gross)
NO
x, pond Hs
mg/kWh
34
52
44
Annual Energy Consumption
Q
HE
GJ
56
81
99
Sound Power Level, Indoors
L
WA
dB
47
50
49
Domestic Hot Water
Q
elec
kWh
0.085
0.087
0.085
ƞ
WH
%
81
82
82
Q
fuel
kWh
7.335
7.235
7.263
AEC
kWh
18
19
18
AFC
GJ
6
5
5
ERP DATA