1.Feature
Ceiling& Foor type A/C (Cooling-only or Heat pump) can be installed under the ceiling and also on the
floor. Compared with normal Floor &Standing type A/C, it can be hoisted under the ceiling,saving room
space, it is also the updating Product for Floor & Standing type A/C.
Application occasions:
Small super market, restaurant, office, meeting room, villa living room, family bedroom, and it can even be
used as the updating Product for modern residential A/C.
Features:
◇
Suspended ceiling, installation under ceiling, saving room space, it is very suitable for family or office
place;
◇
Convenient and flexible for indoor unit installation, can be installed under the ceiling or on the floor;
◇
With Setting or Auto two operation modes, multi fan speed, makes you feel more comfortable;
◇
Shell was formed by mold, and the appearance is “slim”, “elegant”, “fashion” and “comfortable”;
◇
Special insulation design, achieves high heat insulation efficiency and no condensation on shell;
◇
Long term air filter, the wash period is two times longer than normal filter, maintenance is free;
◇
Adopting low noise centrifugal fan, strong wind but quiet operation, the silence design achieves
harmony residential living;
◇
All the installation and maintenance can be done in the bottom of unit, saving the maintenance space;
◇
3-phase power supply type units with low ambient temperature cooling function, which makes the unit
can run normally on the condition that the ambient temperature falls down to -15
℃
;;
◇
Standard remote controller and optional wired controller;
◇
Auxiliary electric heater for heat pump unit, with fast heating and low ambient temperature heating
functions;
◇
Failure automatic detection, if there is a failure, the indicator will flash and the failure code will display
on the wired controller, the failure cause is easier to be found..
◇
Filter to dismantle to wash convenience, don't need to make use of any tool, can move to dismantle to
filter a net to clean.
◇
Ultra slim design, the thickness only 205 mm, and have vertical and horizontal swing function.
Содержание ICC(ICA)-**HR-SA6-NI
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ...21 ...
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ...50 ...
Страница 51: ...54 ...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 67: ...540 760 111 539 257 287 322 130 300 326 590 800 540 4 10 19 370 ...
Страница 68: ...130 370 4 10 19 540 800 690 326 300 606 332 400 354 11 71 903 857 ...
Страница 69: ...148 1255 180 945 413 373 4 10 19 585 340 ...
Страница 72: ...152 ...
Страница 73: ......
Страница 74: ......
Страница 75: ...155 Introduction of Control Board QRD SW3F HCE1 outdoor unit board sockets Power supply 380V 415V ...
Страница 104: ...186 7 Failure analysis Wired controller communication failure ...
Страница 105: ...187 Communication failure between indoor and outdoor unit ...
Страница 106: ...188 Outdoor protection phase sequence ...
Страница 107: ...189 Cooling high pressure protection ...
Страница 108: ...190 Heating high pressure protection ...
Страница 109: ...191 Cooling low pressure protection ...
Страница 110: ...192 Heating low pressure protection ...
Страница 111: ...193 Cooling exhaust temperature protection ...
Страница 112: ...194 Heating exhaust temperature protection ...
Страница 113: ...195 Refrigerant shortage or four way valve failure protection ...
Страница 114: ...196 Sensor failure protection ...
Страница 115: ...197 No action after power on ...
Страница 116: ...198 Poor effect ...
Страница 117: ...199 ...
Страница 118: ...200 Abnormal sound or viberation ...
Страница 119: ...201 ...
Страница 120: ...202 Abnormal odor ...
Страница 121: ...203 Air switch action when air conditioner starting up ...
Страница 122: ...204 Air conditioner water leakage ...