42
kW
10.6
10.6
14.0
Heating
Btu/h
/
40000
/
kW
/
11.7
/
Electric
Data
Rated Cooling Power Input
kW
3.77
3.77
4.87
Rated Heating Power Input
kW
/
3.50
/
Rated Cooling Current
A
7.22
7.22
9.32
Rated Heating Current
A
/
6.69
/
Performan
ce
EER
W/W
2.81
2.81
2.87
COP
W/W
/
3.34
/
Indoor Fan
Fotor
Model
YSK-70W-4
YSK-70W-4
YSK-105W-4
Brand
HUATE
HUATE
HUATE
Output Power x Fan
quantity
W
70
70
105
Capacitor
uF
4
4
5
Speed (Hi/Mi/Lo)
r/min
1380/1100/970
1380/1100/970
1380/1100/970
Indoor Coil
Number Of Row
3
3
3
Tube Pitch(a)x Row
Pitch(b)
mm
22×19.05
22×19.05
20.5×12.7
Fin Spacing
mm
1.6
1.6
1.6
Fin Material
Hydrophilic aluminum fin
Tube Outside Dia.and
Material
mm
φ7.94
,
Inner grooved
φ7.94
,
Inner
grooved
Φ7
,
Inner grooved
Coil Length x Height x
Width
mm
950×264×57.15
950×264×57.15
1300×246×38.1
Heat Exchanging Area
m
2
14.56
14.56
13.69
Indoor Unit
Indoor Air Flow (Hi/Mi/Lo)
m
3
/h
1500/1200/1050
1500/1200/1050
1800/1440/1260
Noise Level(Hi/Mi/Lo)
dB(A)
50/47/41
50/47/41
51/48/42
Net Dimension (W*H*D)
mm
1280×660×205
1280×660×205
1631×660×205
Packing Dimension
(W*H*D)
mm
1360×720×280
1360×720×280
1710×720×280
Net Weight
Kg
33
33
44
Gross Weight
Kg
38
38
50
Refrigeran
t Pipe
Liquid Side
mm
9.52
9.52
9.52
Gas Side
mm
15.88
15.88
19.05
Max. Refrigerant Pipe
Length
m
50
50
50
Max. Difference In Level
m
30
30
30
Operation Temperature Range
℃
16~32
16~32
16~32
Ambient Temperature
Range(Cooling/Heating)
℃
-5~45
-5~45/-15~24
-5~45
Application Area
m
2
42-70
42-70
56-93
Connection
Wiring
Power Wiring( Indoor)
mm
2
3×1mm
2
3×1mm
2
3×1mm
2
Power Wiring( Outdoor)
mm
2
5×2.5mm
2
5×2.5mm
2
5×2.5mm
2
Содержание ICC(ICA)-**HR-SA6-NI
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ...21 ...
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ...50 ...
Страница 51: ...54 ...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 67: ...540 760 111 539 257 287 322 130 300 326 590 800 540 4 10 19 370 ...
Страница 68: ...130 370 4 10 19 540 800 690 326 300 606 332 400 354 11 71 903 857 ...
Страница 69: ...148 1255 180 945 413 373 4 10 19 585 340 ...
Страница 72: ...152 ...
Страница 73: ......
Страница 74: ......
Страница 75: ...155 Introduction of Control Board QRD SW3F HCE1 outdoor unit board sockets Power supply 380V 415V ...
Страница 104: ...186 7 Failure analysis Wired controller communication failure ...
Страница 105: ...187 Communication failure between indoor and outdoor unit ...
Страница 106: ...188 Outdoor protection phase sequence ...
Страница 107: ...189 Cooling high pressure protection ...
Страница 108: ...190 Heating high pressure protection ...
Страница 109: ...191 Cooling low pressure protection ...
Страница 110: ...192 Heating low pressure protection ...
Страница 111: ...193 Cooling exhaust temperature protection ...
Страница 112: ...194 Heating exhaust temperature protection ...
Страница 113: ...195 Refrigerant shortage or four way valve failure protection ...
Страница 114: ...196 Sensor failure protection ...
Страница 115: ...197 No action after power on ...
Страница 116: ...198 Poor effect ...
Страница 117: ...199 ...
Страница 118: ...200 Abnormal sound or viberation ...
Страница 119: ...201 ...
Страница 120: ...202 Abnormal odor ...
Страница 121: ...203 Air switch action when air conditioner starting up ...
Страница 122: ...204 Air conditioner water leakage ...