3. Poor efficiency explanation
During the process of using air conditioner, some phenomenon seems to be malfunction but actually not.
Thus when cooling effect does not
achieve
to your expectation, the following factors have to be
ruled out
Phenomenon
Causing explanation
High outside temperature and too many
indoor individuals, even air conditioner runs at
full-load operation, the wind blowing out from
air outlet is cold, but it is difficult to lower the
indoor temperature, this is not malfunction.
When the outdoor temperature is higher, more heat penetrates into
indoor space, which increases the cooling load of AC. If there are too
many individuals(for example 10 individuals) and every individual gives
off 120W, totally 1200W, this will running out of half of AC cooling
capacity, and the unit’s cooling capacity this time is far from enough,
indoor temperature is hard to lower down. It is normal phenomenon and
do not mean useless of AC.
Power voltage is too low, causing AC uneasy
to start and shut down after starting, or fuse
be burned out etc.
It is not malfunction, need to find out the causing, if the causing is the
electricity net voltage is too low, user should load a power manostat to
keep voltage between 220V-380V for AC normally running
Select
high
wind
speed
but
indoor
temperature still at high side, air flow from the
air outlet is too weak.
It is because air filter is too dirty or blocked making cooling capacity fail to
be brought by air flow, causing cooling capacity inadequate. Take out
filter and wash, the problem will be solved.
Select high wind speed, the vibration and
sound of unit are severe.
Fan runs at high speed, severe vibration and sound of unit is normal
phenomenon
Temperature controller adjusts improper and
max
cooling
capacity
is
not
utilized
completely, thus indoor temperature can’t
lower down.
Adjust the temperature controller, and problem will be solved.
As for Heat pump air conditioner heating
effect is not ideal during cold winter, this is
normal phenomenon.
The lowest temperature is
-
7
℃
when heating, below this temperature
unit cannot heat effectively.
Improper installation will lead to indoor
temperature uneven or bad cooling effect.
It is necessary to adjust AC installation position
Содержание ICC(ICA)-**HR-SA6-NI
Страница 1: ......
Страница 3: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ...21 ...
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ...50 ...
Страница 51: ...54 ...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 67: ...540 760 111 539 257 287 322 130 300 326 590 800 540 4 10 19 370 ...
Страница 68: ...130 370 4 10 19 540 800 690 326 300 606 332 400 354 11 71 903 857 ...
Страница 69: ...148 1255 180 945 413 373 4 10 19 585 340 ...
Страница 72: ...152 ...
Страница 73: ......
Страница 74: ......
Страница 75: ...155 Introduction of Control Board QRD SW3F HCE1 outdoor unit board sockets Power supply 380V 415V ...
Страница 104: ...186 7 Failure analysis Wired controller communication failure ...
Страница 105: ...187 Communication failure between indoor and outdoor unit ...
Страница 106: ...188 Outdoor protection phase sequence ...
Страница 107: ...189 Cooling high pressure protection ...
Страница 108: ...190 Heating high pressure protection ...
Страница 109: ...191 Cooling low pressure protection ...
Страница 110: ...192 Heating low pressure protection ...
Страница 111: ...193 Cooling exhaust temperature protection ...
Страница 112: ...194 Heating exhaust temperature protection ...
Страница 113: ...195 Refrigerant shortage or four way valve failure protection ...
Страница 114: ...196 Sensor failure protection ...
Страница 115: ...197 No action after power on ...
Страница 116: ...198 Poor effect ...
Страница 117: ...199 ...
Страница 118: ...200 Abnormal sound or viberation ...
Страница 119: ...201 ...
Страница 120: ...202 Abnormal odor ...
Страница 121: ...203 Air switch action when air conditioner starting up ...
Страница 122: ...204 Air conditioner water leakage ...