Inputs Table (PRT-IVO-IF-EU)
This section applies only to the European variant of the Inovonics Receiver Module (PRT-IVO-IF-EU).
Refer to the table below to correctly program the specific button/input that will trigger the input operation.
Wireless Transmitter
Product
Code
Input
Number
Physical
Link
Alarm
Messages
Universal Transmitter Dual Inputs with Wall
Tamper
EE1216
1
Input 1
Case Tamper
Low Battery
2
Input 2
Water Resistant Pendant Single Button
EE1223S
1
Button Press Low Battery
Water Resistant Pendant Double Button
EE1223D
1
Both
Buttons
Case Tamper
Low Battery
Belt Clip Transmitter Double Button
EE1235D
1
Both
Buttons
Low Battery
Ceiling Mount PIR
EE1265
1
Sensor
Tamper
Low Battery
Input States
The inputs that are linked to the Inovonics devices will appear in one of four states in a status list. Each state is
outlined below:
Input
State
Description
Closed
The input is closed and in normal operating state, registered and polling with the module
Open
The input has been triggered and received by the module
Tamper
The case tamper has been triggered on an Inovonics device and received by the module
Short
Circuit
The Inovonics device has lost polling with the module and is offline. This will take place
approximately 30 minutes after loss of polling with the module
Trouble Inputs
Each Inovonics receiver module can monitor 2 trouble inputs used to report trouble conditions such as module
communications problems.
Trouble inputs are used to monitor the module status and in most cases are not physically connected to an
external input.
The following table details the trouble inputs that are configured in the system and the trouble type and group
that they activate.
Input Number
Description
Type
Group
RDxxx:01
Module Tamper
Tamper
System
RDxxx:16
Module Communication
Module Lost
System
Replace 'xxx' with the appropriate address of the module that you are programming.
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual
22