background image

Safety Information 

 

Important Safety Information 

  Installation and removal of the PoE  Midspan must be 

carried out by qualified personnel only.  

  The external power supply for the equipment shall be a 

Listed, Direct Plug In power unit, marked Class 2, or 
Listed ITE Power Supply, marked LPS, which has 
suitably rated output voltage, and current. 

  AC Power inlet Set: 

 

The power connector  supplied with the PoE 
Midspan has 2 terminals (See Figure 2) –  

The polarity of the input connection  is not 
important.

  

 

The power inlet  cables  must be rated for 
minimum current capacity of 6 Amperes (Stranded

 

Tinned Copper  12 AWG for each terminal or 
2X16 AWG for each terminal).  

 

Before connecting power inlet  cables to the 
connector terminals verify that the power source 
is turned off. 

 

After insertion of cable inlet  to the connector 
terminals tightly  fasten  all 4 connector screws 
(See Figure 2). 

 

This clause is optional: 
Only for improved EMI performance, connect chassis 
ground connection to "Earth/Ground" connection at 
the working area. 

 

There is no safety hazard when the chassis ground    

connection is not connected to the "Earth/Ground". 

 

:

 The PoE injector "DATA IN" and "DATA & POWER OUT" 

ports are shielded RJ45  data  sockets. They cannot be 

used as Plain Old Telephone Service (POTS) sockets. Only 
RJ45 data connectors may be connected to these sockets.  
 

The 

24

VAC  power source  must be near the PoE  Midspan and 

easily accessible. You can remove AC power from the PoE 
Midspan by disconnecting the 

24

VAC power inlet from either the 

24

VAC power source or the PoE Midspan power connector.  

 

The  PoE  Midspan  "DATA IN"  and  "DATA & POWER OUT" 
interfaces are qualified as SELV (Safety Extra-Low Voltage) 
circuits according to IEC 60950-1. These interfaces can only be 
connected to SELV interfaces on other equipment.

 

 

WARNINGS!   

 

Read the installation instructions before connecting the PoE 
Midspan to its power source. 

 

Follow basic electricity safety measures whenever connecting 
the PoE Midspan to its power source. 

 

A voltage mismatch can cause equipment damage and may 
pose a fire hazard. If the voltage indicated on the label is 
different from the power outlet voltage, do not connect the PoE 
Midspan to this power outlet. 

 

Take extra attention when connecting the power inlet 
terminals, so they will not touch chassis ground.

 

Mounting Instructions 

Perform the following instructions:

 

1. 

Install two screws in the wall or shelf as shown in Figure 1. 

 

Figure 1: PoE Midspan mounting instructions  

 

2. 

Align the PD-9501G/24AC mounting slots to capture the surface 
screws 

 

 

Recycling and Disposal

 

Disposal instructions for old products. The WEEE (Waste 
Electrical and Electronic Equipment) national environmental 
initiatives has been put in place to ensure that products are 
recycled using best available treatment, recovery and 
recycling techniques to ensure human health and high 
environmental protection. Your product is designed and 
manufactured with high quality materials and components, 
which can be recycled and reused. Do not dispose of your 
old product in your general household waste bin. Inform 
yourself about the local separate collection system for 
electrical and electronic products marked by this symbol:

 

 

Use one of the following disposal options :

 

1. Dispose of the complete product (including its cables, 
plugs and accessories) in the designated WEEE collection 
facilities.

 

2. If you purchase a replacement product, hand your 
complete old product back to the retailer. He should accept 
it as required by the national WEEE legislation.

 
 

 Microsemi Corp. 

 

Ordering information:  

  Product Name:

 Microsemi 9501G/24AC 

  Part Number:

 PD-9501G/24AC 

  Description:

 1-Port 802.3at 4-Pairs Gigabit PoE Midspan 

 

Document P/N PD9501G24AC_UG-EN Rev. B00

 

 

 

0B

Microsemi 9501G/24AC  

1B

User Guide 

 

2B

1-Port 802.3at 4-Pairs Gigabit PoE 
Midspan, 24VAC input. 

 

 

 
 
 
 
 
 

 

Notice 

 

It is Microsemi’s policy to improve its products as 
new technology, components, software, and firmware 
become available. Microsemi, therefore, reserves the 
 right to change specifications without prior notice. 

 

Technical Support 

If you encounter problems when installing or using this 
product, please consult the Microsemi website at: 
http://www.microsemi.com 
 
For technical support, call: +972-9-775-5123 
In the USA: 1-877-480-2323 
Email: [email protected]  
 
 

 

 