![background image](http://html1.mh-extra.com/html/ics/p110/p110_user-manual_3534742010.webp)
10 ► P110 User Manual
OPERATION
Figure 2.
Hydraulic Connections
If adapter fittings are used, they must be approved
steel hydraulic fittings meeting a minimum operating
pressure rating of 2500 psi/172 bar. Do not use
galvanized pipe fittings or black pipe fittings.
Use thread tape or pipe joint compound when installing
quick disconnect couplings to hose or tool fittings.
Follow the instructions furnished with the selected
thread sealant. DO NOT OVERTIGHTEN THE
FITTINGS.
6. BATTERY
The supplied 12-Volt DC battery is a non-spillable,
maintenance-free battery and is fully charged.
Make sure the battery cables are tight and charging
circuit functions are operating properly.
NOTICE
Do not charge the battery with a standard automotive
battery charger. This type of charger produces a
charging amperage higher than 2 amps. Charging
the battery at higher than 2 amps will damage the
battery.
NOTICE
If the engine runs out of gas or dies during operation
and the ignition switch is left in the ON or RUN
position, this could drain the battery. Make sure the
ignition switch is returned to the OFF position.
CONTROL PANEL
RETURN
PRESSURE
HTMA 1/2 INCH MALE
QUICK DISCONNECT
COUPLER
HTMA 1/2 INCH FEMALE
QUICK DISCONNECT
COUPLER
1/2 INCH I.D. HOSE, 25 FT
LONG WITH 2500 PSI/
172 BAR RATING AND
4 TO 1 SAFETY FACTOR
PRESSURE
RETURN
1/2 INCH MALE PIPE HOSE END
1/2 INCH MALE PIPE HOSE END
ADAPTER, 3/8 INCH MALE PIPE
×
-8 SAE O-RING
HTMA 1/2 INCH MALE
QUICK DISCONNECT
COUPLER
HTMA 1/2 INCH FEMALE
QUICK DISCONNECT
COUPLER
TOOL
RETURN
PRESSURE