OPERATION
COLD WEATHER STARTUP
1. Use the procedures described under “STARTUP”
and then follow the procedure below.
2.
Hydraulic fluids are thicker in cold weather.
Therefore, it is recommended that the engine
be run at low idle long enough to bring the fluid
temperature up to a minimum of 50 °F/10 °C.
3. If the tools and tool hoses are cold, it is
recommended to allow hydraulic fluid to circulate
through the tool hoses until warm before using the
tool.
SHUTDOWN
1.
Ensure the flow selector switch in the OFF position
(center position).
2. Unless already at idle the power unit should return
to idle. This may take a few seconds for the unit to
react due to a built-in program delay.
3. Allow the engine to idle for approximately one
minute and move the Ignition Switch to the OFF
position.