iKAN Series Display User Manual v 1.0.1 Page: 93
3. Enter the following value, and then click the
Update
button
i. In the
Source Low
column, enter the minimum value of the integer value.
ii. In the
Source High
column, enter the maximum value of the integer value.
iii. In the
Target Low
column, enter the minimum value of the physical value.
iv. In the
Target High
column, enter the maximum value of the physical value.
v. From the
Decimal Places
column, select the desired number of decimal places to be used for
the converted value.
The value for integer variable 1 will be shown on the iKAN display, but will now use the scaled
value text rather than the integer value.
Input Voltage: 32767 V
Input Voltage: 5.00 V