iKAN Series Display User Manual v 1.0.1 Page: 92
2. Consider the arguments for data mapping
For example, to convert a 16-bit unsigned integer (0 to 65535) to the voltage 0 to 10 V, set the
following arguments:
Argument
Value
Description
Source Low
0
The minimum value of the integer
Target Low
0
The minimum value of the physical value
Source High
65535
The maximum value of the integer
Target High
10
The maximum value of the physical value
Decimal Places
-
The number of decimal places to be used for the converted value
Target High
Target Low
Source High
Source Low