41600
0640
1
Brightness for the display, a smaller
number means a brighter screen
0 to 4
R/W
41601
0641
1
Message scrolling speed. A smaller
value denotes a greater speed.
0 to 9
R/W
41602
0642
1
Modbus Station ID
1 to 254
R/W
41604
0644
1
Modbus TCP Slave port
0 to 65535
R/W
41612
0652
1
The response timeout value for
Modbus TCP communication
0 to 65535
R/W
41613
0653
1
The delay between polls for
Modbus TCP communication
0 to 65535
R/W
41632
:
41759
0660
:
06DF
128
The priority for messages 0 to 127
0: Common
1: Instant
R/W
41800
:
41831
0708
:
0727
32
The contents of ASCII string 0
ASCII
R/W
41832
:
41863
0728
:
0747
32
The contents of ASCII string 1
ASCII
R/W
41864
:
41895
0748
:
0767
32
The contents of ASCII string 2
ASCII
R/W
41896
:
41927
0768
:
0787
32
The contents of ASCII string 3
ASCII
R/W
41928
:
41959
0788
:
07A7
32
The contents of ASCII string 4
ASCII
R/W
41960
:
41991
07A8
:
07C7
32
The contents of ASCII string 5
ASCII
R/W
41992
:
42023
07C8
:
07E7
32
The contents of ASCII string 6
ASCII
R/W