![background image](http://html1.mh-extra.com/html/icp-das-usa/ikan-series/ikan-series_user-manual_3565344106.webp)
iKAN Series Display User Manual v 1.0.1 Page: 106
41024
:
41087
0400
:
043F
64
Decimal Places for float-type
variables
1 to 3
R/W
41408
:
41535
0580
:
05FF
128
Color for common messages 0 to
127 in the first row.
1: Blue
2: Green
3: Sky Blue
4: Red
5: Purple
6: Yellow
7: White
8: Random
R/W
41600
0640
1
Brightness for the display, a
smaller number means a brighter
screen
0 to 4
R/W
41601
0641
1
Message scrolling speed. A
smaller value denotes a higher
speed.
0 to 9
R/W
41602
0642
1
Modbus Station ID
1 to 254
R/W
41604
0644
1
Modbus TCP Slave port
0 to 65535
R/W
41612
0652
1
The response timeout value for
Modbus TCP communication
0 to 65535
R/W
41613
0653
1
The delay between polls for
Modbus TCP communication
0 to 65535
R/W
41632
:
41759
0660
:
06DF
128
The priority for messages 0 to
127
0: Common
1: Instant
R/W
41800
:
41831
0708
:
0727
32
The contents of ASCII string 0
ASCII
R/W
41832
:
41863
0728
:
0747
32
The contents of ASCII string 1
ASCII
R/W