2.2.3
Jumper and Switch Settings
JP 7 provides control over
the EMG-A signal of the CON6 connector. The
following diagram shows the jumper positions and its corresponding
states.
Fig. 2.6 Jumper 7 setting
JP8/9, JP10/11, JP12/13, JP14/15: Jumper 8~15 are used to set the signal type of
the pulse output signals. The output signal type could be differential line driver
output (2-3 Pin short )or open collector output(1-2 Pin short).