ET-2200 Series Ethernet I/O Modules
Copyright © 2020 ICP DAS CO., Ltd. All Rights Reserved.
-72 -
Step 2
Locate the ”mosquitto.exe” file in the default installation path and double-click it to
enable the Mosquitto server.
Why can’t I open ”mosquitto.exe” or why does it crash?
Once the Mosquitto installation is complete, the Broker server will be automatically enabled by
default when the computer boots. Therefore, the Broker is already enabled after the computer
reboots. At this time, clicking the “mosquitto.exe” file again will be the same as attempting to
enable an already enabled-Broker server, and the attempt will be blocked.
To prevent the broker from automatically opening, you must change the settings in the
Windows Services application.
Open the Services application by searching for “Services”.
When this window is executing, the Broker is enabled.
Closing this window will disable the Broker.