CLOSING FORCE
If the door is obstructed from closing (ie. due to obstruction, jam, etc.) this current
monitoring feature will stop and reverse the door to prevent damage. The
sensitivity of this monitoring can be changed in this setting, or the feature can be
turned off entirely.
Closing Force sensitivity can be adjusted from 1-20 (1 being most sensitive to
obstructions/jams/imbalance) or OFF. Factory default is ‘3’.
OPEN SLOW SPEED
When the door is approaching open limit and decelerates down to slow speed
before the stop (Soft Stop), added force/speed may be required to complete
opening. While this is indcative of an improperly balanced door, this feature
can be used to compensate. This setting should only be changed from the
NORMAL to the HIGH setting if door
becomes
unbalanced over time and does
not completely travel to Open limit. If it is a new installation, changing the spring
tension for proper balance is a required first step. Factory default is ‘NORMAL’.
CLOSE SLOW SPEED
When the door is approaching Close Limit and decelerates down to slow speed
before the stop (Soft Stop), added force/speed may be required to complete
closing. While this is indcative of an improperly balanced door, this feature
can be used to compensate. This setting should only be changed from the
NORMAL to the HIGH setting if door
becomes
unbalanced over time and does
not completely travel to Close limit. If it is a new installation, changing the spring
tension for proper balance is a required first step. Factory default is ‘NORMAL’.
OPEN RAMPDOWN DISTANCE
This setting is used to change the point where the door begins to decelerate
to slow speed as it approaches the Open Limit. The user can choose between
auto (which is configured by the system) or the desired number of shaft rotations
(between 0.5 turns and 3 turns in half rotation increments).
The Factory setting for this feature is AUTO. This should not be changed unless
recommended by Pulse Technical Support.
CLOSE RAMPDOWN
DISTANCE
This setting is used to change the point where the door begins to decelerate
to slow speed as it approaches the Close Limit. The user can choose between
auto (which is configured by the system) or the desired number of shaft rotations
(between 0.5 turns and 3 turns in half rotation increments).
The Factory setting for this feature is AUTO. This should not be changed unless
recommended by Pulse Technical Support.
OPEN LIMIT OPTIONS (PUSH BUTTON)
This setting allows the user to choose between the SET LIMIT or the FULLY OPEN limit
for the "OPEN" button on the control panel or the "O" terminal (Push Button Station
Inputs) on the control circuit board.
OPEN LIMIT OPTIONS (REMOTE RADIO)
This setting allows the user to choose between the set limit or the fully open limit
for the "REMOTE RADIO" connections on the control circuit board.
Содержание PULSE
Страница 7: ...7 TORQUE ARM POSITION IN RELATION TO OPERATOR ...
Страница 13: ...13 WIRING DIAGRAMS ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 26: ...26 PULSE OPERATOR COMPONENTS ...