VOLTAGE RANGE
NOTE: USING AN INCORRECT VOLTAGE SETTING COULD LEAD TO THE
DOOR OPERATING AT AN UNSAFE SPEED.
This operator is designed to work with
SINGLE PHASE
voltages from 110-240Vac
(for 3 phase voltage, use optional external transformer). There are 2 available
settings, 110-130V or 208-240V, and proper selection for your installation
MUST
to be made prior to operation. Failure to do so could result in damage to the
operator and door. To access this option, toggle between menu options using
the OPEN or CLOSE buttons until VOLTAGE SETUP appears on the screen. Then
press the STOP button to select. Press OPEN or CLOSE to toggle between Voltage
Selections. Press STOP to Save and return to the STARTUP MENU.
MOTOR POSITION
NOTE: NOT SETTING THE CORRECT MOTOR POSITION WILL RESULT IN THE
DOOR NOT CLOSING PROPERLY.
Factory default is LEFT SIDE. If the Operator is installed on the RIGHT SIDE, push the
STOP button to enter this menu setting, then toggle with the OPEN or CLOSE button
to change to RIGHT SIDE. To save your selection and exit to the STARTUP MENU
options, press the STOP button.
DOOR LIMITS
NOTE: PROGRAMMING OF LIMITS SHOULD BE PERFORMED BY TRAINED
PERSONNEL ONLY. THE ENCODER WILL RETAIN THESE LIMITS UNTIL RE-
PROGRAMMED.
Press the STOP button to set the limits. Once selected, DOOR LIMITS heading will
appear with a prompt to ‘Push OPEN to Start'. Push the OPEN button, and the door
will open to the fully open position against the Limit Brackets. ENSURE THAT THE TOP
ROLLERS OF THE DOOR ARE RESTING AGAINST THE LIMIT BRACKETS. The Open Limit
now needs to be set.
SET OPEN LIMIT
Press CLOSE (OPEN functional should you overshoot desired position) to jog
the door to the desired Open Limit height.
The Open Limit Setting Should be a
minimum offset of 3" from the Limit Bracket or Open Limit Switch
. Press STOP
button to save Open Limit and advance to SET CLOSE LIMIT.
SET CLOSE LIMIT
From the Open Limit, jog to the desired Close position, using the CLOSE button
(OPEN available for fine tuning). Ensure that the door is properly sealed at the
bottom.
Press STOP button to save and return to STARTUP MENU.
SETTING DOOR SPEEDS
On initial set up please use the factory default MEDIUM speed. As noted below the Motor, Door and
Drum size may affect the opening speed of the door and the Medium setting may be all that is
required to achieve 24” per second opening speed
Please note that the Pulse has been developed with the same technology that is used in High Speed Door Operators.
While we have limited the maximum opening speed to ~24” per second for sectional doors (this is dependent on
the type of door and drum used) and maximum closing speed to ~16” per second, we recommend that you set the
speed to accommodate both your requirement, and the hardware of the door. To get the longest life out of your door,
and to maximize your allowable speed, we recommend Stainless Steel cables and nylon rollers be installed if they
are not already standard on your door.