Control Panel Mounting
The control panel should be securely mounted at
or around eye level (minimum 5 ft. from floor) on
the same side as the operator/junction box. Ensure
that the control panel is mounted far enough away
from the door as to avoid user contact with the
door while in operation, but close enough that the
user has clear view of the door at all times. Four (4)
control mounting brackets are provided to facilitate
mounting. See Fig: 8
Photo-Eye or Thru-Beam Sensor Mounting
The included reflective photo-eye or thru-beam
sensor should be mounted so that it scans area
that spans the entire width of the door at a height
of no more than 6 inches from the ground. The
sensor (reflective photo-eye) or receiver (thru-beam)
should be mounted on the operator side (as it will
be wired into the control panel), while the reflector
or transmitter should be mounted on the opposite
side of the door, facing the sensor/receiver so that its
center meets the beam. Use the included mounting
bracket(s) to secure to either the door tracks or the
wall. Refer to the specific mounting details provided
with the sensor. For final alignment of the sensor, put
unit in STARTUP MENU (see page 18) to apply power to
the sensor (after WIRING – see page 13 for additional
wiring diagram). Once properly aligned in STARTUP
MENU, the indicator will light up in confirmation. Note
that upon exit from the STARTUP MENU, the sensor will
only become active when the door is closing.
See Fig: 9 for mounting reference.
FIGURE: 8
FIGURE: 9