5-9
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
VU3-flat
106 VU3 flat (1150 M)
• Set the test equipment to set as
shown below:
Frequency: 1150.0215
MHz
Modulation: None
Level: +40
dB
μ
†
(–67 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound 1
seconds later.)
107 VU3 flat (1100 M)
• Set the test equipment to:
Frequency: 1100.0215
MHz
108 VU3 flat (1220 M)
• Set the test equipment to:
Frequency: 1220.0215
MHz
109 VU3 flat (1249 M)
• Set the test equipment to:
Frequency: 1249.9815
MHz
110 VU3 flat (1375 M)
• Set the test equipment to:
Frequency: 1375.0215
MHz
111 VU3 flat (1330 M)
• Set the test equipment to:
Frequency: 1330.0215
MHz
112 VU3 flat (1420 M)
• Set the test equipment to:
Frequency: 1420.0215
MHz
113 VU3 flat (1499 M)
• Set the test equipment to:
Frequency: 1499.9815
MHz
114 VU3 flat (1575 M)
• Set the test equipment to:
Frequency: 1575.0215
MHz
115 VU3 flat (1500 M)
• Set the test equipment to:
Frequency: 1500.0215
MHz
116 VU3 flat (1650 M)
• Set the test equipment to:
Frequency: 1650.0215
MHz
117 VU3 flat (1749 M)
• Set the test equipment to:
Frequency: 1749.9815
MHz
118 VU3 flat (1875 M)
• Set the test equipment to:
Frequency: 1875.0215
MHz
119 VU3 flat (1750 M)
• Set the test equipment to:
Frequency: 1750.0215
MHz
120 VU3 flat (1830 M)
• Set the test equipment to:
Frequency: 1830.0215
MHz
121 VU3 flat (1920 M)
• Set the test equipment to:
Frequency: 1920.0215
MHz
122 VU3 flat (1999 M)
• Set the test equipment to:
Frequency: 1999.9815
MHz
123 VU3 PRE flat (1150 M)
• Set the test equipment to:
Frequency: 1150.0215
MHz
124 VU3 PRE flat (1375 M)
• Set the test equipment to:
Frequency: 1375.0215
MHz
125 VU3 PRE flat (1575 M)
• Set the test equipment to:
Frequency: 1575.0215
MHz
126 VU3 PRE flat (1875 M)
• Set the test equipment to:
Frequency: 1875.0215
MHz
VU4 TOTAL GAIN
(Preamp OFF)
127 VU4 Total Gain PRE OFF ref
• Set the test equipment to set as
shown below:
Frequency: 2424.0215
MHz
Modulation: None
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
128 VU4 Total Gain PRE OFF set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
VU4 TOTAL GAIN
(Preamp ON)
129 VU4 Total Gain PRE ON ref
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
130 VU4 Total Gain PRE ON set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
5-4
VU RECEIVE ADJUSTMENT (CONTINUED)
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.