5-10
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
VU4 S-METER
131 VU4 S0 LEVEL
• Set the test equipment to set as
shown below:
Frequency: 2424.0215
MHz
Modulation: None
Level: 0
dB
μ
†
(–107 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound 1
seconds later.)
132 VU4 S9 LEVEL
• Set the test equipment level to:
Level: +34
dB
μ
†
(–73 dBm)
133 VU4 S9+60 LEVEL
• Set the test equipment level to:
Level: +94
dB
μ
†
(–13 dBm)
134 VU4 dBu –10dB
• Set the test equipment level to:
Level: –10
dB
μ
†
(–117 dBm)
135 VU4 dBu 0dB
• Set the test equipment level to:
Level: 0
dB
μ
† (–107 dBm)
136 VU4 dBu 10dB
• Set the test equipment level to:
Level: +10
dB
μ
†
(–97 dBm)
137 VU4 dBu 20dB
• Set the test equipment level to:
Level: +20
dB
μ
†
(–87 dBm)
138 VU4 dBu 40dB
• Set the test equipment level to:
Level: +40
dB
μ
†
(–67 dBm)
139 VU4 dBu 60dB
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
140 VU4 dBu 80dB
• Set the test equipment level to:
Level: +80
dB
μ
†
(–27 dBm)
VU5-flat
141 VU4 flat (2075 M)
• Set the test equipment to:
Frequency: 2075.0215
MHz
Modulation: None
Level: +40
dB
μ
†
(–67 dBm)
142 VU4 flat (2000 M)
• Set the test equipment to:
Frequency: 2000.0215
MHz
143 VU4 flat (2150 M)
• Set the test equipment to:
Frequency: 2150.0215
MHz
144 VU4 flat (2249 M)
• Set the test equipment to:
Frequency: 2249.9815
MHz
145 VU4 flat (2375 M)
• Set the test equipment to:
Frequency: 2375.0215
MHz
146 VU4 flat (2250 M)
• Set the test equipment to:
Frequency: 2250.0215
MHz
147 VU4 flat (2330 M)
• Set the test equipment to:
Frequency: 2330.0215
MHz
148 VU4 flat (2499 M)
• Set the test equipment to:
Frequency: 2499.9815
MHz
149 VU4 flat (2625 M)
• Set the test equipment to:
Frequency: 2625.0215
MHz
150 VU4 flat (2500 M)
• Set the test equipment to:
Frequency: 2500.0215
MHz
151 VU4 flat (2575 M)
• Set the test equipment to:
Frequency: 2575.0215
MHz
152 VU4 flat (2749 M)
• Set the test equipment to:
Frequency: 2749.9815
MHz
153 VU4 flat (2875 M)
• Set the test equipment to:
Frequency: 2875.0215
MHz
154 VU4 flat (2750 M)
• Set the test equipment to:
Frequency: 2750.0215
MHz
155 VU4 flat (2830 M)
• Set the test equipment to:
Frequency: 2830.0215
MHz
156 VU4 flat (2920 M)
• Set the test equipment to:
Frequency: 2920.0215
MHz
157 VU4 flat (2999 M)
• Set the test equipment to:
Frequency: 2999.9815
MHz
158 VU4 PRE flat (2075 M)
• Set the test equipment to:
Frequency: 2075.0215
MHz
159 VU4 PRE flat (2375 M)
• Set the test equipment to:
Frequency: 2375.0215
MHz
160 VU4 PRE flat (2625 M)
• Set the test equipment to:
Frequency: 2625.0215
MHz
161 VU4 PRE flat (2875 M)
• Set the test equipment to:
Frequency: 2875.0215
MHz
• After the adjustment, the receiver shows the VHF/UHF receive adjustment menu.
• Push [EXIT] to return to the main menu screen.
5-4
VU RECEIVE ADJUSTMENT (CONTINUED)
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.